Velleman PIR416 Mode D'emploi page 5

Masquer les pouces Voir aussi pour PIR416:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
6. Connect the wiring [1] to the terminals according to the diagram
on page 2. Wire colours:
x red (+)
Warning: do not short-circuit any terminals.
7. Connect the power supply.
8. To test the PIR sensor, set the light sensitivity to OFF and the
movement sensitivity and 5" to ON. The load should switch on
immediately and – when no movement is detected – switch off
after 5 s.
Note: DO NOT change the DIP switch settings when power is
connected!
5.
Technical Specifications
switch type
detection angle
detection range
rated load
input
output
working temperature -10 °C to +40 °C
working humidity
time-delay switch
light control
dimensions
weight
Use this device with original accessories only. Velleman nv
cannot be held responsible in the event of damage or injury
resulting from (incorrect) use of this device. For more info
concerning this product and the latest version of this manual,
please visit our website www.velleman.eu. The information in
this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All
worldwide rights reserved. No part of this manual may be copied,
reproduced, translated or reduced to any electronic medium or
otherwise without the prior written consent of the copyright holder.
V. 04 – 26/03/2013
PIR416
y black (-)
relay
100°
8 m (@ 22 °C)
25 W resistive load
12 Vdc, 2.6 A
max. 12 Vdc 2.5 A / 25 W
< 93 % RH
5 s, 30 s, 1 min, 3 min, 5 min, 8 min
< 3 lx to 2000 lx
visible part
hidden part (controller) 55 x 25 x 35 mm
± 41 g
5
z brown
Ø 22 x 10 mm
©Velleman nv

Publicité

Table des Matières
loading

Table des Matières