Problem
The electronic board remains
The machine does not heat
GB
correctly
Insufficient humidity in
proving chamber
Deformed water inlet pipe
(high pressure inside boiler).
Power supply cable incorrectly connected.
off.
Protective Klixon (PTRC) interrupted.
Water inlet electrovalve malfunctioning
Vapour inlet electrovalve malfunctioning
Malfunctioning sensor or level control
Vapour inlet electrovalve malfunctioning
Malfunctioning sensor or level control
Causes
Interrupted fuses
Check heating element
Evaporator fan blocked
Closed water cock
Clogged water filter
Boiler resistance not working
Check humidity sensor
Blocked boiler safety valve
No pressure reducer
20
Solutions
Check the electric
connection
Check and replace fuses
Check and replace the
component.
Check connections and
resistance
Contact the after-
sales centre.
Open water inlet cock
Clean filter
Replace component
Check and replace the
component.
Check and replace the
component.
Check if the value of the
probe is correct
Check and replace the
component.
Check and replace the
component.
Check and replace the
component.
Check and insert the
reducer inside water inlet
valve
Check and replace the
component.