Fasten the drill stand securely on a firm, flat
surface using the specified and undamaged
installation materials.
If the drill stand can slip or wobble, the drill or
drive unit cannot be guided uniformly and safely.
Disconnect the plug of the drill or drive unit
from the socket before mounting the drill or
drive unit on the drill stand, make any unit
settings or change accessory parts.
Unintentional starting of drills or drive units
causes accidents.
Fix the drill or drive unit securely onto the
drill stand as specified before starting work.
Slipping of the drill or drive unit on the drill stand
can cause loss of control and injuries.
Remove all setting tools, spanners and
installation materials not required before
switching on the drill or drive unit.
Setting tools, spanners and installation materials
located in/on a rotating part of the unit can result
in injuries.
Do not overload the drill stand and do not
use it as a ladder or scaffolding.
Overloading or standing on the drill stand can
cause the centre of gravity of the drill stand to
move upwards and the drill stand overturns.
When fixing the drill stand on the workpiece
using anchors and screws, ensure that the
anchoring used is able to hold the machine
safely during use.
If the workpiece is not resistant or is porous, the
anchor can be pulled out, which causes the drill
stand to detach from the workpiece.
If fixing the drill stand on the workpiece by
means of a vacuum plate, ensure that the
surface is smooth, clean and not porous.
Do not fix the drill stand onto laminated
surfaces, such as tiles and facings of
composite materials.
If the surface of the workpiece is not smooth,
flat or adequately fixed, the vacuum plate can
detach from the workpiece.
Before and while drilling, ensure that the
vacuum is sufficient.
If the vacuum is insufficient, the vacuum plate
can detach from the workpiece.
| 34 |
Never carry out overhead drilling and drilling
in the wall, if the machine is only fixed by
means of a vacuum plate.
In the event of loss of vacuum, the vacuum plate
detaches from the workpiece.
Do not use any accessories that have not
been especially provided and recommended
for this drill stand by the manufacturer.
Just because you can attach accessories to your
drill stand is not a guarantee of safe use.
Additional signs or other, non-BAIER-
specific parts must not be screwed or
riveted onto the drill stand.
This could damage the drill stand and cause
malfunctions to occur.
Note and follow all safety and work
instructions for the accessories used.
Never place the feed crank handle on the
hexagon of the tapered shaft to tighten it.
Excessive torques could damage it.
2.6.9 Service / Maintenance / Repair
If the power tool is dropped or becomes wet,
have it checked.
A possibly damaged power tool is dangerous
and no longer safe to operate. Before using
the power tool again, have it checked by our
customer service or an authorised service
centre of Maschinenfabrik OTTO BAIER GmbH.
Repair and maintenance work may only be
carried out by an authorised workshop of
Maschinenfabrik OTTO BAIER GmbH.
Otherwise, all liability and warranty claims
against Maschinenfabrik OTTO BAIER GmbH
expire.
NOTE
When using new carbon brushes, the machine may
only be operated within the green range for the first
15 minutes - observe LED display in the handle.