POSABLE INDUCTION / FREE STANDING INDUCTION
AL2 3500 F AP
INTERCONNECTION:
Power line cord
190VAC à 260VAC, 50 Hz ou 60 Hz
ZOOM
NO CONSIDERATION OF THE CONTRACTUAL GUARANTEE MANUFACTURER:
Vitro glass breakage or cracking (with flat or wok unit)
Breakage of the adjustment knob aWer a bad using.
Failure aWer an interven on on the power cord ( replacing of the plug, cut of the cord, plucking of
the cord or degrada on of the cord)
Consequen al failure resul ng in improper electrical connec on on the main line (ex: 400V instead
of 230V)
Failure following product disassembly and/or aWer an interven on inside the unit
Failure due to lack of product maintenance (air filter not clean or clogged)
Failure following the absence of the air filter or due to the presence of water, foreign body or fluids
HOW TO DISCONNECT THE CONNECTIONS INSIDE PRODUCT:
1 - Be sure that the unit is disconnected of the main line
2 - Open the vitroceram top casing
3 - Disconnect the keyboard with precau on. It is necessary to hold the connector of the flat cable with 2 fin-
gers. You should not remove directly the flat cable.
4 - During the reassembly, It is necessary to be sure of the good connec on of the keyboard and also of the
good connec on of the power cord sockets.