POSABLE INDUCTION / FREE STANDING INDUCTION
AL2 3500 F AP
Affichage Erreur
clavier
ER.01
In vitro sensor in short circuit slave home
ER.02
In vitro sensor cut off or absent slave home
ER.03
Sensor in vitro short-circuit master focus
ER.04
In vitro sensor cut off or absent master fireplace
ER.05
IGBT sensor shorted
ER.05
Sensor temperature generator card cut or missing
ER.06
IGBT temperature sensor switched off or missing
ER.06
Sensor temperature generator in short circuit
ER.07
Temperature on IGBT too high
ER.08
The temperature of the in vitro sensor does not vary
ER.13
One or more fans missing or defec ve
ER.14
One or more fans missing or defec ve
ER.15
Measuring fault of the induc ve current
ER.16
Failure to measure the phase of the induc ve current
ER.18
Internal 13.8-volt generator voltage fault
ER.29
Analogue safety fault
ER.31
Slave generator communica on fault
ER.09
Mains voltage below 85 Vac
ER.20
Mains frequency below 285 Hz
ER.10
Line voltage greater than 285 Vac
ER.19
Mains frequency greater than 70 Hz
Out of life of the fuse : Standard exchange of the generator kit (power part is out of life).
The replacement of the fuse does not allows the restart of the product.
Electroménager Professionnel / Professional Appliances
Causes poten elles

ERROR CODES

Interven on
AFTER SALES
AFTER SALES
AFTER SALES
AFTER SALES
AFTER SALES
AFTER SALES
AFTER SALES
AFTER SALES
Press on / off key to acknowledge fault, or dis-
connect / reconnect product.
Press the on / off key to acknowledge the fault
or disconnect / reconnect product. If error code
s ll present: Call AWer sales service.