Electrical Hook-Up - Bradford White KwickShot TEF024V120 Guide D'installation Et Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

BEFORE BEGINNING ANY WORK ON THIS INSTALLATION, CONFIRM THE ELECTRICAL
BREAKER IS "OFF" AND THAT ALL MOUNTING AND PLUMBING WORK HAS BEEN
COMPLETED PER THE STATED INSTRUCTIONS.
For use on an individual branch circuit only. The heater shall be installed using insulated, UL listed, 2 wire cable (2
wire plus ground) of the appropriate size suitable for up to 75°C and protected by the correctly rated circuit breaker.
Refer to the chart below for recommended copper wiring for conductors with a temperature rating of 75°C:
Flow Controlled
Thermostatic
Models
Models
TEF024V120
TEF030V120
TEF035V120
TEF035V240
TEF048V240
TEF055V240
TET055V240
TEF065V240
TET065V240
TEF075V240
TET075V240
TEF095V240
TET095V240
TET115V240
TEF030V208
TEF041V208
TEF083V208
TET083V208
TEF030V277
TEF041V277
TEF060V277
TET060V277
TEF080V277
TET080V277
TEF090V277
TET090V277
TEF100V277
TET100V277
*Recommendation for special suffixed models (i.e. CA, ML), are identical to standard models.
Information contained in this document is subject to change without notice.
SECTION 4: ELECTRICAL HOOK-UP
Voltage
(VAC)
120
120
120
240
240
240
240
240
240
240
208
208
208
277
277
277
277
277
277
Max
Max
Minimum
power
current
wire size
(AWG)
(kW)
(A)
@75°C
2.4
20
14
3
25
12
3.5
29
10
3.5
15
14
4.8
20
14
5.5
23
12
6.5
27
10
7.5
32
10
9.5
40
8
11.5
48
8
3
15
14
4.1
20
14
8.3
40
8
3
11
14
4.1
14.8
14
6
22
12
8
29
10
9
33
10
10
36
8
238-54367-00A REV 09/21