SECTION 6: KwickShot® THERMOSTATIC MODEL OPERATION
Factory temperature setpoints/maximum adjustable range:
KwickShot®
Thermostatic
models
Base Model
<4kW
>4kW
ML (Multi Lavatory)
CHANGING SETPOINT TEMPERATURE
To INCREASE temperature, tap the "+" button repeatedly, or hold the "+" down to INCREASE the temperature quickly. To
DECREASE temperature, tap the "–" button repeatedly, or hold the "–" down to DECREASE the temperature quickly.

ADVANCED FUNCTIONS

With the display showing the current setpoint temperature, press BOTH "+" AND "–" buttons simultaneously for 3 seconds.
Screen Info
Title
Flow Rate
FLO
Inlet temperature
IN
Outlet temperature
OUT
Power Factor
PF
Software Revision
SR
Hold "-" to display the current screen title.
Press "+" to advance to the next screen.
Holding both "+" and "–" at any time for 3 seconds returns the display to the temperature set point, or just let the heater
return to set point display on its own after a period of time.
ERROR CODES & UNITS
From Advanced Menu, press and hold the "+" and "–" buttons for 10 seconds.
Screen Info
Title
Current Error(s)
CE
Past Errors
PE
Units
UN
Eco Mode*
ECO
* Thermostatic models only
Pressing "-" at any time will display screen title (CE, PE1-5, UN, ECO).
Press the "+" button for 1 second to cycle through the following screens:
To return to setpoint hold "+" and "–" for 10 seconds, or just let the heater return to setpoint display or display turn-off on
its own after a period of time.
Information contained in this document is subject to change without notice.
Default
Minimum
Maximum
Setpoint
Setpoint
Setpoint
(°F)
(°F)
(°F)
105
70
140
120
110
70
110
Units
Description
GPM or LPM
Current water flow rate through unit
°F or °C
Cold water temperature
°F or °C
Hot water temperature
%
How hard the heater is working
-
For Technical Support assistance
Description
Any errors currently present (F0 displays if no errors are present)
Previous 5 errors and faults
Choose between °F/GPM and °C/LPM
Toggle non-silent operation