For optimum performance, Bradford White recommends the use of isolation valves (full flow ball type) on the inlet and
outlet pipes and a 40 mesh Y-Strainer on the inlet of the heater.
Clean the screen periodically for best performance.
BEFORE ATTEMPTING ANY INSTALLATION, MODIFICATION OR SERVICE OF THIS
HEATER, MAKE SURE THE ELECTRICAL POWER IS DISCONNECTED.
The heater's water INLET and OUTLET are labeled. Install full flow ball
valves to the inlet and outlet pipes and run water through the inlet
pipe into a bucket to purge it of any debris. Close the inlet ball valve.
*Failure to do so may clog the inlet water screen.
Make sure the inlet filter screen is present in the inlet fitting and the inlet
and outlet pipes are correctly aligned with the heater connections to
minimize stress on the heater.
Remove the cover. Connect the pre-assembled inlet and outlet pipes to the
heater (do not overtighten compression fittings) and fully open the inlet
and outlet ball valves. Check the system for water leaks at all plumbing
connections. If a leak is present at the compression fitting, slowly tighten
compression nut until it stops – do not overtighten.
Information contained in this document is subject to change without notice.