• Minimum turn on flow rates are family dependent:
o
Thermostatic Models: 0.2 GPM
o
Flow Controlled Models: vary by model (refer
to the table below)
The water heater is supplied with 3/8" brass compression fittings that are compatible with either copper or plastic pipes.
Make sure these fittings are used for this installation. Contact your representative for further information.
NEVER SUBSTITUTE THREADED PIPE FITTINGS USING PIPE DOPE OR TEFLON TAPE AND
NEVER SOLDER ANY PIPE CONNECTIONS WHILE ATTACHED TO THIS HEATER AS
DAMAGE TO THE HEATER WILL RESULT. DOING THIS WILL VOID THE WARRANTY!
Bradford White strongly recommends that the heater be supplied directly from the main cold-water trunk line when
possible. This helps to avoid a potential water flow interruption to the water heater which could lead to a failure of the
heating element.

System Requirements:

Base Model*
TEF024V120
TEF030V120
TEF035V120
TEF035V240
TEF048V240
TEF055V240
TEF065V240
TEF075V240
TEF095V240
TEF030V208
TEF041V208
TET083V208
TEF030V277
TEF041V277
TEF060V277
TEF080V277
TEF090V277
TEF100V277
*Special suffixed models (i.e. CA, ML), will have identical temperature rises as their base model
Information contained in this document is subject to change without notice.
Remove the cover and fasten to the wall using the mounting holes at
each corner of the back plate. Replace the cover.
SECTION 3: PLUMBING HOOK-UP
Turn On Flow Rate, GPM (LPM)
0.2
0.25
0.3
(0.76)
(0.95)
(1.14)
Minimum/maximum working pressure: 30
PSI/150 PSI (Optimal operating pressure range:
35 to 80 PSI)
0.4
0.5
0.7
(1.51)
(1.89)
(2.65)
0.8
(3.03)
238-54367-00A REV 09/21