Mounting; Cable Entry - WERMA Signaltechnik 738 100 55 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

310_783_001_0509.fm Seite 10 Dienstag, 19. Mai 2009 2:50 14
738
red
yellow
Voltage
Current consumption
Temperature class (gas)
Surface temp. (dust)
Waiting time before opening
782
red
yellow
Voltage
Power Consumtion
Current consumption
Temperature class (gas)
Surface temp. (dust)
Waiting time before opening
783
red
yellow
Voltage
Halogen bulb
Current consumption
Temperature class (gas)
Waiting time before opening
784
red
yellow
Voltage
Current consumption
Temperature class (gas)
Surface temp. (dust)
Waiting time before opening
6

Mounting

For dimensions and mounting see "Zeichnungen / Drawings / Dessins"
page 18.
Caution:
When the signal housing is mounted with the glass dome facing down, the
recessed plug is permanently filled with water. This can be avoided by closing
this opening with a putty material after mounting.
7

Cable entry

The standard light fitting is always provided with 2 M20 lead-in holes, one
cable entry and 1 plug are enclosed.
10
738 100 55
738 100 67
738 300 55
738 300 67
24 V=
700 mA
T5
85 °C
30 min
782 100 55
782 120 68
782 120 55
782 300 55
782 320 68
782 320 55
24 V=
115 – 230 V~
782 x0x xx: 5W / 782 x2x xx: 3,6W
max. 200 mA
70 – 180 mA
T6
80 °C
30 min
783 110 75
783 100 75
783 100 77
783 310 75
783 300 75
783 300 77
24 V≅
24 V≅
20 W
35 W
900 mA
1,6 A
T4
T3
3 min
3 min
784 100 75
784 100 77
784 300 75
784 300 77
24 V≅
1,6 A
T4
105 °C
3 min
738 100 68
738 300 68
115 V~
230 V~
300 mA
200 mA
T5
T5
90 °C
85 °C
30 min
30 min
782 100 68
782 300 68
230 V~
50 mA
T6
T6
80 °C
80 °C
30 min
30 min
783 110 68
783 100 68
783 310 68
783 300 68
115 V≅
230 V~
35 W
20 W
350 mA
110 mA
170 mA
T3
T4
-
-
784 100 68
784 300 68
115 V≅
230 V~
350 mA
170 mA
T4
T4
105 °C
105 °C
-
-
230 V~
35 W
T3
-