Mounting; Commissioning; Servicing; Cleaning - WERMA Signaltechnik 761 Mode D'emploi

Masquer les pouces Voir aussi pour 761:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

310_761_003_0305_A5.fm Seite 7 Mittwoch, 16. März 2005 4:35 16
Temperature range
Duty cycle
Protection type according to IEC 60529
Explosion protection
for gas
Explosion protection
for dust
Test certificate
5.2
Electrical data
Type
Rated current
761 000 55
24 V=
761 000 65
24 V~, 50 Hz
761 000 66
42 V - 48 V~, 50 Hz
761 000 67
115 V~, 50/60 Hz
120 V~, 60 Hz
761 000 68
230 V~, 50 Hz
6

Mounting

For dimensions and mounting see "Zeichnungen / Drawings / Dessins"
page 11.
7

Commissioning

Before commissioning make sure that:
• the appliance has been mounted according to instructions,
• the electrical connections have been carried out correctly,
• the appliance is not damaged in any way.
8

Servicing

The appliance is maintenance-free
9

Cleaning

Zone 1:
• Clean only with a damp cloth using water or mild non-chafing, non-
scratching cleaning fluid. Never use aggressive substances or solvents
when cleaning.
Zone 21:
• Clean with a cloth, brush, vacuum-cleaner or similar. For wet cleaning use
water or mild non-chafing, non-scratching cleaning fluid. Never use
aggressive substances or solvents when cleaning.
10

Disposal

Observe national waste disposal regulations when disposing of the appliance!
-40 °C ... + 50 °C
70%
IP 65
II 2G EEx me II T5
II 2D IP65 T 70 °C
BVS 03 ATEX E 118X
Voltage range
Current
consumption
21,6 ... 26,4 V
350 mA
21,6 ... 26,4 V
450 mA
37,8 ... 52,8 V
220 mA
102,5 ... 126,5 V
205 mA
108 ... 131 V
220 mA
208 ... 250 V
70 mA
Mounting
Fuse to be
connected in series
F 0,5 A
F 0,63 A
F 0,315 A
F 0,315 A
F 0,125 A
7

Publicité

Table des Matières
loading

Table des Matières