Settings; Adjusting The Water Temperature - Jaga BRIZA 22-JFCC Manuel

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1. 
2.  SETTINGS
2.1.  ADJUSTING THE WATER TEMPERATURE
2.1.1.  Setting the maximum water temperature for cooling
By setting the temperature lower, the unit will start later. If the water
temperature is set higher, the unit will start faster .
1. Start setup mode: hold the [-] button until
2. Briefly press the [-] or [+] button to adjust the set temperature .
RS485 A/B
I2C
PC / RF
CO2
POWER 45W
INPUT: 110-240VAC
OUTPUT: 24V
Tsens 1
CONTROL PANEL
Tsens 2
Tsens 3
THERMOSTATE 1
ON
Tsens 4
N L
GND 0-10V 24V
1
2
3
4
5
6
7
8
GND
24V
DIPSWITCH
JAGA
GND
24V
GND
NTC1
GND
0-10V +24V
+24V
RC
GND
IN/OUT
GND
0-10V
V.H.
GND
0-10V
V.C.
The blue LED
minimum temperature is reached.
Automatic control:
set temperature
3. Exit setup mode: hold the [-] button until
2.1.2.  set minimum water temperature heating
By setting the temperature higher, the unit will start later. If the water temperature is set lower, the
unit will start faster .
When using a heat pump, it may be necessary to set the water temperature at a lower setting .
1. Exit setup mode: hold the [+] button until
2. Briefly press the [-] or [+] button to adjust the set temperature .
RS485 A/B
I2C
PC / RF
CO2
POWER 45W
INPUT: 110-240VAC
OUTPUT: 24V
Tsens 1
CONTROL PANEL
Tsens 2
Tsens 3
THERMOSTATE 1
ON
Tsens 4
N L
1
2
3
4
5
6
7
8
GND 0-10V 24V
GND
24V
DIPSWITCH
JAGA
GND
24V
GND
NTC1
GND
0-10V +24V
+24V
RC
GND
IN/OUT
GND
0-10V
V.H.
GND
0-10V
V.C.
The blue LED
minimum temperature is reached.
Automatic control:
temperature .
3. Exit setup mode: hold the [+] button until
After 30 seconds, the new settings are automatically saved and the device returns to the
selected mode.
JAGA NV | BRIZA 22 - JFCC | MANUEL | 23.08.2021 | V.07
12 ̊ C
14 ̊ C
16 ̊ C
flashes quickly as soon as the
The green LED
lights up when the water temperature (supply water) is lower than the
the
the red LED
24 ̊ C
26 ̊ C
28 ̊ C
flashes quickly as soon as the
The green LED
lights when the water temperature (supply water) exceeds the set
the red LED
the
blue LED
flashes 5x and release .
18 ̊ C
20 ̊ C
22 ̊ C
24 ̊ C
The red LED
maximum temperature is reached.
blue LED
flashes 5x and release .
flashes 5x and release .
30 ̊ C
32 ̊ C
34 ̊ C
36 ̊ C
The red LED
maximum temperature is reached.
flashes 5x and release .
RS485 A/B
I2C
PC / RF
CO2
26 ̊ C
ON
GND 0-10V 24V
1
2
3
4
GND
24V
GND
24V
GND
NTC1
GND
0-10V +24V
+24V
RC
GND
IN/OUT
flashes quickly as soon as the
RS485 A/B
I2C
PC / RF
CO2
38 ̊ C
ON
1
2
3
4
GND 0-10V 24V
GND
24V
GND
24V
GND
NTC1
GND
0-10V +24V
+24V
RC
GND
IN/OUT
flashes quickly as soon as the
POWER 45W
INPUT: 110-240VAC
OUTPUT: 24V
Tsens 1
Tsens 2
Tsens 3
Tsens 4
N L
GND
0-10V
V.H.
GND
0-10V
V.C.
EN
POWER 45W
INPUT: 110-240VAC
OUTPUT: 24V
Tsens 1
Tsens 2
Tsens 3
Tsens 4
N L
GND
0-10V
V.H.
GND
0-10V
V.C.
51

Publicité

Table des Matières
loading

Table des Matières