B.1.  FACTORY SETTINGS
The device is controlled via auto-change-over. The unit starts as soon as the set water
temperature has been reached. The user can temporarily select another mode manually.
Auto-change-over. The unit starts at the last selected speed(1, 2 or 3), as soon as the water
temperature > 28 ̊ C .
Only with configuration code FCC.BRC62 / FCC.BRC64!
Auto-change-over. The unit starts at the last selected speed(1, 2 or 3), as soon as the water tempera-
ture < 18 ̊ C .
The unit is in standby. The unit automatically starts a new cycle as soon as the set temperature
has been reached.
Permanently off All functions are disabled until the user switches on the unit via the control panel.
Activator speed is set according to the unit's length.
B.2.  CONTROL
Press the button until the desired mode is
reached (± 3 sec.)
When auto-change-over mode the controller
itself will select the desired operation mode.
The user can always choose manually a
different mode of operation.
Manually raising / lowering the fan speed :
MODE
1
2
3
Fanspeed : 1
Red LEDs
are flashing in the set mode: the water temperature of the supplied water is too low
(Tw < 28 ̊ C ).
Blue LEDs
are flashing in the set mode: the water temperature of the supplied water is too high
(Tw > 18 ̊ C ).
Window contact
The window contact is not activated by default and has to be activated /deactiva-
ON
ted manually .
1
2
3
4
5
6
7
8
Switch on : turn on the DIP switch 1
JAGA NV | BRIZA 22 - JFCC | MANUEL | 23.08.2021 | V.07
MODE
1
2
3
Fanspeed : 2
ON
1
3"
3"
3"
Only with configuration code
FCC.BRC62 / FCC.BRC64!
MODE
1
2
Fanspeed : 3
EN
3
45