Designation system for the Optyma™ Plus range
OP - MPXM
034 ML P00 G
1 2 3 4
5
1 Application
M = MBP
L = LBP
2 Package
Condensing unit family: P = Optyma™ Plus
3 Refrigerant
H = R404A/R507
G = R134a, R513A
Q = R452A, R404A/R507
X = R404A/R507, R134a, R407A, R407F, R448A, R513A
R449A,R452A
Y = R404A/R507, R449A
B = R448A/R449A/R404A/R452A (MBP)
P = R448A/R449A, R407A/F, R404A/R507
O = R448A/R449A/R404A/R452A (LBP)
4 Condenser
M = Microchannel heat condenser
5 Swept volume
Displacement in cm
Example 034 = 34 cm
3:
6 Compressor platform
ML= Fixed speed scroll MLZ
7 Version
P00: Optyma™ Plus
P02: Optyma™ Plus with Liquid Injection
P05: Optyma™ Plus with Supply monitoring relay
8 Voltage code
G = 230V/1-phase/50Hz compressor & fan
E = 400V/3-phase/50Hz compressor & 230V/1-phase fan
1 – Introduction
These
instructions
pertain
ma
Plus
condensing
units
OP-MPXM, OP-MPGM, OP-LPQM, OP-LPOM & OP-
MPBM used for refrigeration systems. They pro-
vide necessary information regarding safety and
proper usage of this product.
The condensing unit includes following:
• Microchannel heat exchanger
• Reciprocating or scroll compressor
• Receiver with stop valve
• Ball valves
• Sight glass
• High & low pressure switches
• Replaceable filter drier
• Electronic controller
• Main circuit breaker (Main switch with overload
protection)
• Fan and compressor capacitors
• Compressor contactor
• Supply monitoring relay**
• Robust weather proof housing
• Liquid injection controller (Module B Plus)*
• Electronic expansion valve (ETS6)*
*Only for P02 version,
**only for P05 models
© Danfoss | Climate Solutions | 2021.07
6
7
8
Version control
3
* Inbuilt function within Condensing unit electronic controller
2 – Handling and storage
to
Opty-
• It is recommended not to open the packaging
OP-MPYM,
before the unit is at the final place for installa-
tion.
• Handle the unit with care. The packaging al-
lows for the use of a forklift or pallet jack. Use
appropriate and safe lifting equipment..
• Store and transport the unit in an upright posi-
tion.
• Store the unit between -35°C and 50°C.
• Don't expose the packaging to rain or corrosive
atmosphere.
• After unpacking, check that the unit is com-
plete and undamaged.
3 – Installation precautions
Never place the unit in a flammable atmos-
phere.
Place the unit in such a way that it is not bloc-
king or hindering walking areas, doors, windows
or similar.
• Ensure adequate space around the unit for air
circulation and to open doors. Refer to picture
1 for minimal values of distance to walls.
• Avoid installing the unit in locations which are
daily exposed to direct sunshine for longer pe-
riods.
Optyma™ Plus
IP level
Compressor technology
Control box (pre-wired E-panel)
Microchannel condenser
Fan speed controller*
Main switch (circuit breaker)
Supply monitoring relay
Filter drier (flare connections)
Sight glass
Crankcase heater
HP/LP adjustable pressostat
Fail safe mini-pressostat
Access door(s)
Acoustic insulation
Condensing unit electronic controller
Network connectivity
Stack mounting
Discharge gas thermostat
HP/LP Alarm
Liquid injection kit, phase loss/
sequence protection
(P00)
(P02)
IP54
IP54
Scroll/
Scroll
Reciprocating
yes
yes
yes
yes
yes
yes
yes
yes
-
-
yes
yes
yes
yes
yes
yes
Electronic
Electronic
Mechanical
Mechanical
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
-
yes
• Avoid installing the unit in aggressive and dus-
ty environments.
• Ensure a foundation with horizontal surface
(less than 3° slope), strong and stable enough
to carry the entire unit weight and to eliminate
vibrations and interference.
• The unit ambient temperature may not exceed
50°C during off-cycle.
• Ensure that the power supply corresponds to
the unit characteristics (see nameplate).
• When installing units for HFC refrigerants, use
equipment specifically reserved for HFC refri-
gerants which was never used for CFC or HCFC
refrigerants.
• Use clean and dehydrated refrigeration-grade
copper tubes and silver alloy brazing material.
• Use clean and dehydrated system components.
• The suction piping connected to the compres-
sor must be flexible in 3 dimensions to dampen
vibrations. Furthermore piping has to be done
in such a way that oil return for the compres-
sor is ensured and the risk of liquid slug over in
compressor is eliminated.
4 – Installation
• The installation in which the condensing unit is
installed must comply to pressure Equipment
Directive (PED) 2014/68/EU. The condensing unit
118U3276D - AN18658643414604-001501 | 3
(P05)
IP54
Scroll (3phase)
yes
yes
yes
yes
yes
yes
yes
yes
Electronic
Mechanical
yes
yes
yes
yes
yes
yes
yes
-