Calibration
The meter needs to be calibrated and tested on a regular basis to
ensure it produces accurate measurement results. We recommend
carrying out calibration once a year.

Technical data

Function
DC voltage
AC voltage
DC current
AC current
Resistance
Capacitance
Frequency
24
GB
Range
400.0 mV
4.000 V
40.00 V
400.0 V
600 V
400.0 mV
4.000 V
40.00 V
400.0 V
600 V
10 A
10 A
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
40.000 nF
400.0 nF
4.000 µF
40.00 µF
100.0 µF
9.999 Hz
99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
999.9 kHz
9.999 MHz
Accuracy
± (0.5% rdg ± 2 digits)
± (1.2% rdg ± 2 digits)
± (1.5% rdg ± 2 digits)
± (1.5% rdg ± 4 mV)
± (1.2% rdg ± 2 digits)
± (1.5% rdg ± 3 digits)
± (2.0% rdg ± 4 digits)
± (2.5% rdg ± 5 digits)
± (3.0% rdg ± 7 digits)
± (1.2% rdg ± 4 digits)
± (1.0% rdg ± 2 digits)
± (1.2% rdg ± 2 digits)
± (2.0% rdg ± 3 digits)
± (5.0% rdg ± 50 digits)
± (3.0% rdg ± 5 digits)
± (5.0% rdg ± 5 digits)
± (1.5% rdg ± 5 digits)
± (1.2% rdg ± 3 digits)
± (1.5% rdg ± 4 digits)