Resistance Measurement - LaserLiner MultiMeter-Compact Mode D'emploi

Masquer les pouces Voir aussi pour MultiMeter-Compact:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 60
All manuals and user guides at all-guides.com
5
Voltage measurement DC/AC
To take a voltage measurement, turn the
rotary switch to position „V" and press the
„Mode" button to set the voltage mode
(AC, DC). Then connect the measuring
contacts to the object to be tested. The
measured value acquired and the polarity
appear on the display.
6

Resistance measurement

To measure the resistance, turn the rotary
switch to position „Ω". Then connect
the measuring contacts to the object to
be tested. The measured value acquired
appears on the display. If „O.L." appears
on the display instead of a measured
value, either the measuring range has
been exceeded or the measuring circuit
is not closed or has been interrupted.
Resistances can only be measured
correctly in isolation; therefore, the
components might need to be
disconnected from the remainder
of the circuit.
When measuring resistance, to avoid the risk of the results
!
of a measurement being distorted, there must be no traces
of dirt, oil, solder spray or other contamination on the test
prods.
MultiMeter-Compact
Black
Black
Red
Red
19