Télécharger Imprimer la page

Chicago Pneumatic CP 4123 Prescriptions De Sécurité Et Instructions Pour L'opérateur page 13

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
www.CrowderSupply.com • Toll Free: 888-883-5144
CP 4123, CP 4125
Water separator
The length of the air hose between the compressor
and the water separator must be such that the
water vapor is cooled and condenses in the hose
before reaching the water separator.
The required hose length is dependant on the
ambient temperature and the relative humidity.
If the ambient temperature is below 32 °F (0 °C)
the hose must be short enough to prevent the
water from freezing before reaching the water
separator.
lubrication
The lubricant is important for the machine's
function and has a great impact on the service
life. In order to supply the correct volume of oil, a
lubricator should be connected to the air hose. The
use of the Chicago Pneumatic Air Line Lubricator is
recommended. To guarantee good lubrication, the
length of the air hose between the lubricator and
the pneumatic hammer should not exceed 10 feet
(3 m).
Too much lubrication may cause starting
problems, low power or uneven performance.
Recommended Lubricant: Air tool oil with a
viscosity of 100-150 SUS at 100°F (ISO VG 22–32).
It is recommended that the oil contains a rust-
inhibitor.
inserted tool
Choosing inserted tool
A correct inserted tool is a condition for good
operation. To avoid unnecessary machine damage,
it is important to choose inserted tools with a high
quality.
Recommended inserted tools are listed in the
machine's spare parts list.
The narrow chisel should be used for demolition and
cutting work in concrete and other types of hard
material.
9800 0606 90
Safety and Operating instructions
The moil point should only be used for creating holes in
concrete and other types of hard material.
The wide chisel should be used in soft materials e.g.
plaster and removal of tiles.
Always use a sharp tool to be able to work
effectively. A worn out tool causes increased
vibrations and the operation will take longer.
Fitting and removing the inserted tool
Warning
Starting the machine while changing the inserted
tool may cause personal injury. Before changing
the tool, stop the machine, switch off the
compressed air supply and bleed the machine by
activating the start and stop device.
Whenever fitting the inserted tool the following
instructions must be observed:
Before inserting a tool, lubricate the tool shank
with grease.
When the tool is inserted, fit the cap and check
the lock function by pulling the inserted tool
sharply outwards.
13

Publicité

loading

Ce manuel est également adapté pour:

Cp 4125