OPERATION
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
1. STOP! Read the safety information on the attached plate.
2. Check that gas supply to heater is on.
3. Set the thermostat to the lowest setting. (If applicable).
4. Push in gas control knob slightly and turn clockwise
to "OFF" position. Do not force.
Model DVAG 11, DVAG17 and 30
NOTE: Knob cannot be turned from "PILOT" to "OFF"
unless knob is pushed in slightly. Do not force.
5. Wait five (5) minutes to clear out any gas. If you then
smell gas, STOP! Follow "B" in the safety information
above this label. If you don't smell gas, go to the next
step.
6. Find pilot. The pilot can be seen through the view port on
the top of the appliance.
1.
Set thermostat to lowest setting. (If applicable).
2. Turn control knob clockwise
CAUTION:Wait five (5) minutes before re-lighting heater.
DO NOT TRY TO ADJUST HEATING LEVELS BY USING THE MANUAL SHUTOFF VALVE.
• DO NOT DRY CLOTHES OVER THE HEATER.
• DO NOT SPRAY ANY AEROSOL NEAR THE HEATER WHEN FUNCTIONING. DO NOT STORE THESE
ELEMENTS NEAR THE APPLIANCE.
• DO NOT TOUCH GRILL TO AVOID BURNS.
• AVOID BLOCKING AIR INLET AND HOT AIR OUTLET.
• DO NOT SPILL WATER OVER THE HEATER AS IT MAY CAUSE CORROSION OR DAMAGE.
• DO NOT TOUCH VENT CAP WHILE HEATER IS OPERATING, TO AVOID BURNS.
• IF YOU SMELL GAS, SHUT OFF CONTROL VALVE, OPEN DOORS AND WINDOWS AND DO NOT
LIGHT ANY ELECTRICAL FIXTURE NEAR THE HEATER. CALL YOUR GAS SUPPLIER.
WARNING:
damage, personal injury or loss of life.
LIGHTING INSTRUCTIONS
POSITION INDICATOR
TO TURN OFF GAS TO APPLIANCE
to the "OFF" position. Do not Force.
CAUTION:
IMPORTANT:
15
Pliot Burner
Model DVAG11, DVAV17 and 30
7. Turn gas control knob counterclockwise
Keep control knob depressed and continuously push the
white piezo button. This should cause the spark from the
ignitor to light the pilot gas. Keep control knob depressed
for ten (10) seconds before releasing. If Pilot does not
light, repeat step 6. NOTE: It may be necessary to press
for thirty (30) seconds if this is first time heater is
connected to the gas supply.If the knob does not pop up
when released, stop and immediately call your service
technician or gas supplier. If the pilot will not stay lit after
several tries, turn the gas control knob to "OFF" and call
your service technician or gas supplier.
8. When pilot is lit, turn the control knob counterclockwise
to desired heating level.
9. Set thermostat to desired setting. (If applicable).
© 2021 United States Stove Company
to "PILOT".
853265