Specifications
pH
Range
Resolution
Accuracy
Calibration
Buffers
Temperature Compensation
ISO-pH
Slope
Range
mV
Resolution
Accuracy
Calibration
Range
CONDUCTIVITY
Resolution
Accuracy
Calibration
Standards
Cell Constant
Temperature Compensation
Reference Temperature
Temperature Coefficient
Capacitive Compensation
Range
DISSOLVED
Resolution
Accuracy
Calibration
Temperature Compensation
Salinity Compensation
OXYGEN
Air Pressure Compensation
FREE CHLORINE
Range
Resolution
Accuracy
Calibration
pH Compensation
Temperature Compensation
Range
TEMPERATURE
Resolution
Accuracy
Calibration
AIR PRESSURE
Range
Calibration
Measurement
CHANNELS
Free Chlorine
Temperature
INPUTS
Measurement
Temperature
CALIBRATION
Reminder
GLP
CONTROL
On/Off
Proportional
Wash program
Alarm timer
DISPLAY
LCD
White Backlight
Real Time Clock
RECORDER
Two Outputs
RS485
Baud Rate
Computer
DATA-LOGGING
Values
Modes
Interval
RELAY OUTPUTS
Relays
Voltage
Identification Number
SECURITY
Password Protection
POWER SUPPLY
Mains
DIMENSIONS
WxDxH
WEIGHT
Meter
29
R361
-2...+16 pH
0.001 pH
0.1% ± 1 digit
1...5 points
9 pre-programmed
-30...+130°C
6...8 pH
80...120%
±2000 mV
0.1 mV
0.1% ± 1 digit
1 point
0...2000 mS/cm
0.001 µS/cm
0.5% f.s. of range
1...3 points
0.01/0.1/1M KCl
0.05...15 cm
-1
-30...+130°C
20° or 25°C
natural waters (EN27888)
ü
0...60 mg/l (0...600%)
0.01 mg/l (0.1%)
1% ± 1 digit
1 point
0...50°C
0...40 ppt
600...1300 hPa
-30...+130°C
0.1°C
0.3°C
1 point
600...1300 hPa
1 point
2
2
2 BNC
2 BNC, for Pt1000
0...999 h
ü
ü
ü
ü
ü
128x64 pixels
ü
ü
4 solid state (*)
12...250 VAC
min. 1 mA/ max. 1 A
ü
210...250 VAC, 50/60 Hz
28x17x6 cm
1.3 kg
R362
-2...+16 pH
0.001 pH
0.1% ± 1 digit
1...5 points
9 pre-programmed
-30...+130°C
6...8 pH
80...120%
±2000 mV
0.1 mV
0.1% ± 1 digit
1 point
0...2000 mS/cm
0.001 µS/cm
0.5% f.s. of range
1...3 points
0.01/0.1/1M KCl
0.05...15 cm
-1
-30...+130°C
20° or 25°C
natural waters (EN27888)
ü
0...60 mg/l (0...600%)
0.01 mg/l (0.1%)
1% ± 1 digit
1 point
0...50°C
0...40 ppt
600...1300 hPa
-30...+130°C
0.1°C
0.3°C
1 point
600...1300 hPa
1 point
2
2
2 BNC
2 BNC, for Pt1000
0...999 h
ü
ü
ü
ü
ü
128x64 pixels
ü
ü
4...20 mA, max. 300 Ω load
300...19200 b/s
via RS485/RS232 interface
12000 + °C/date/time
all
1 s...4 h
4 solid state (*)
12...250 VAC
min. 1 mA/ max. 1 A
ü
ü
210...250 VAC, 50/60 Hz
28x17x6 cm
1.3 kg
R363
-2...+16 pH
0.001 pH
0.1% ± 1 digit
1...5 points
9 pre-programmed
-30...+130°C
6...8 pH
80...120%
±2000 mV
0.1 mV
0.1% ± 1 digit
1 point
0...2000 mS/cm
0.001 µS/cm
0.5% f.s. of range
1...3 points
0.01/0.1/1M KCl
0.05...15 cm
-1
-30...+130°C
20° or 25°C
natural waters (EN27888)
ü
0...60 mg/l (0...600%)
0.01 mg/l (0.1%)
1% ± 1 digit
1 point
0...50°C
0...40 ppt
600...1300 hPa
0...10 mg/l
0.01 mg/l
5% ± 1 digit
1 point
5...9 pH
10...40°C
-30...+130°C
0.1°C
0.3°C
1 point
600...1300 hPa
1 point
2
1
1
3 BNC
1 BNC, for Pt1000
0...999 h
ü
ü
ü
ü
ü
128x64 pixels
ü
ü
4...20 mA, max. 300 Ω load
300...19200 b/s
via RS485/RS232 interface
12000 + °C/date/time
all
1...9999 s
4 solid state (*)
12...250 VAC
min. 1 mA/ max. 1 A
ü
ü
210...250 VAC, 50/60 Hz
28x17x6 cm
1.3 kg
R361 • R362 • R363