Monthly Checks; Cleaning The Cell; General Maintenance - DA-GEN DRYDEN AQUA GENERATOR Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
110-230 V
DRY CONTACT
max. 3.15 A
1 2 3 4 5 6
7 8 9
10 11 12 13 14
ACO
®
AUX 1
3
4
&
11
&
12
APF
®
dosing pump
AUX 4
Heating control
13
&
AUX 2
5
6
&
Automatic
backwash valve
(Besgo)
The auxiliary relays are configured by default.
If you want to reassign the relays for other
accessories, you must access the "Service
Menu".
Contact your authorised installer.
SALT CONCENTRATION:
If necessary, carry out a monthly visual inspection. To clean the cell:
Stop the system and close the valves
1
Place the cell for no more than 10 min. in 3% hydrochloric acid or put it for 2 to 4 hrs in normal vinegar or take a high pressure cleaner.
2
Once the incrustations have softened remove with a hose to complete cleaning the cell.
3
DO NOT USE METALLIC OR SHARP OBJECTS TO REMOVE INCRUSTATIONS. Scratching the edges or surface of the cell will make it
vulnerable to chemicals, deteriorate the cell and invalidate the guarantee.
The pool must be vacuumed as usual and the skimmers emptied whenever necessary.
1
FILTER BACKWASHING: At least once every week for 4 to 5 minutes.
2
VERY IMPORTANT: Make sure the cell is off while cleaning the filter. If the system controls the filtration pump, use the option "backwash" of the programmed filtration
mode. See chapter 13 - automatic backwash
3
Check regularly the level of your pH and APF
4
pH / Redox / Conductivity – probes: The probes must be cleaned and recalibrated every 2 to 3 months. To clean the probe insert in
electrode cleaner. After each clean the probes must be re-calibrated.
Attention: the probes should never dry out and must be kept wet if stored (when emptying the pool for winterising, make sure
to store the probe head in water).
18. AUXILIARY RELAYS
18.1
18.4
14
18.6
19. MAINTENANCE

Monthly checks

~1200 ppm TDS
~2000 μS/cm

Cleaning the Cell

General maintenance

®
bottle to prevent the dosing pump from running dry.
18.2
18.3
18.5
18.3 Manual mode (ON/OFF).
18.4 Automatic mode: ON/OFF according to a timer that adjusts the
start and end of the program. The timers can be configured with a
frequency.
18.5 Timer mode: Working time is programmed in minutes. Each time
the Shortcut on the front panel is pressed, it will start up and run for
18.7
the programmed time. This function is recommended for timing of air
pumps of spas.
18.7 Rename relays: It is posible to rename each auxiliary relay to suit
the use you want to assign. By pressing the plus/minus keys, a pop-up
keyboard will appear. Scroll up and down with the up/down keys and
left to right with the plus/minus keys. To select a letter press the OK.
HYDROLYSIS CELL:
Visual inspection to detect incrustations.
8
18.2 It is possible to control up to 4 extra auxiliary
relays (water attractions, dosing pumps, etc).
In default setting you will only see two available
relays: APF
®
and ACO
®
: (AUX 1 and 3). AUX 2 is
reserved for the Besgo Valve and AUX 4 for the
heating and therefore not shown here. If you do not
have a heating, you can deactivate it (Chapter C & D
in the service manual) and you will get a additional
free relay (AUX4).
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dryden aqua

Table des Matières