D.2 Parameters related to external devices
D.2
D.2 Setting the polarity times. In the case of high alkalinity, the times in
Hydro Pol 1 + 2 should be reduced.
E.1
E.2
E.2 With the plus/minus keys, select
the pump type connected to the system
(the default is a standard pump type).
The configuration allows the control
of two different variable speed pumps
(Variable Speed A or Variable Speed B).
In case of a variable speed pump (A or
B), establish the speed when the cover
is closed, when the pool heating is
connected and/or it controls a backwash
filter (Besgo).
Consult the wiring-schemata in the appendix!
F.1
F.2
F.5
F.6
F.9
F.10
F.10 You can associate the level sensor (TANK) to the pH or chlorine (rX). This menu corresponds to the behavior of
the system after the TANK signal activation (acid deposit level TANK).
Ignore – TANK is not shown in the display
Inform – When the sensor detects that the level is low, the TANK alarm is displayed.
Force stop – When the sensor detects that the level is low, the TANK alarm is displayed and the associated dosing
pump stops.
D) SERVICE SETTINGS
E) TYPE OF PUMP
F) DOSING PUMPS
F.3
F.4
F.7
F.8
11
E.3
E.3 Variable Speed Pump A (Hayward
During the filtration periods, the corresponding relay
closes. The filtration pump opens and closes contacts
depending on the speed:
Common + 1 – Slow speed
Common + 1 + 2 – Medium speed
Common + 1 + 2 + 3 – Fast speed
Variable Speed Pump A B (Speck
the filtration periods, the corresponding relay closes.
It's necessary to connect a wire from the filtration relay
to the common. The filtration pump opens and closes
contacts depending on the speed:
Common + 1 – Slow speed
Common + 2 – Medium speed
Common + 3 – Fast speed
F.2 There are 2 modes for the pH dosing pump:
F.3 Normal: Delay - Delay time between detection of incorrect
value and the start of dosing.
F.4 Repetitive: With the two timers you can programm the ON
and OFF time of the dosing pump
Scaling: Proportional reduction of the dosing time (Pump On
time) when getting close to the setpoint. Example 100%: The
pump time is reduced proportionally if the pH is closer than
1 to the setpoint. Example 50%: The pump time is reduced
proportionally if the pH is closer than 0.5 to the setpoint.
F.6 Other pumps: With the two timers you can programm the
ON and OFF time of the dosing pump
F.8 It corresponds to the behavior of the system after AL3
activation:
Ignore – AL3 is not shown in the display.
Inform – After the selected interval, the AL3 alarm is displayed.
Force stop – After the selected interval, the AL3 alarm is
displayed on the display and the dosing pump stops. To reset
the alarm and the dosing pump, press
®
or similar):
or similar): During
®
.