G.2 Gas (0) - The FL1 alarm is only activated by cell's gas sensor (external flow switch annulled).
G.1
G.2
Siempre ON (1) - The FL1 alarm is never activated (invalidates cell's gas sensor and external flow switch);
Paddle (2) - The FL1 alarm is activated by external flow switch (gas sensor annulled).
Paddle or gas (3) - When both cell's gas sensor and external flow switch are connected, and either of them detects lack of
flow, The FL1 alarm is activated. To connect the external flow switch use the FL1 terminal
Paddle + Gas (4) - When both cell's gas sensor and external flow switch are connected, and both of them detects lack of
flow, The FL1 alarm is activated. To connect the external flow switch use the FL1 terminal
Paddle delay - Delay before FL1 is activated
Relay control through flow detection - Manage the FL1 alarm deactivation in case of lack of flow. Recommended option
for floculant dosification or similar.
H.1
H.2
I.1
I.2
I.2 Node addr: Used for the configuration of more than 2 user interfaces.
For normal operation of the system, keep the value to 1 for this parameter.
K.1
K.2
K.2 Server control and connection port in case there is WIFI Module connected to the system.
For the proper functioning of the system, do not change the default values unless you receive a notice from your provider.
G) EXTRA SETTINGS
H) COUNTERS
H.3
H.2 Reset counters: There are two levels of working hours counters which log the
working hours of the components and devices.
In this service menu the installer can reset the working hour counters on the first
level (for example when a new cell is installed).
The second level of the working hour counters can only be accessed by the factory.
I) CONNECTION
K) WEB IP
12