Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
11
1
8
9
3
6
5
13
14
ACO
A
External pump controller*
B
Filter with AFM
®
C
Filter pump
1
Control Panel
2
Free chlorine cell with rotameter
3
Cell
(always in vertical position if installed without paddle
6
flow switch
)
4
pH probe
5
Redox probe and/or conductivity probe
Conductivity probe
1
yellow
2
transparent
Cover
1
&
5
Chlorine probe detector
FL2
(rotameter)
3
black
5
brown
6
blue
Paddle Flow switch
FL1
2
5
&
Suction lance pH-
Minus
4
&
5
TANK
Temperature probe
1
red
2
yellow
3
black
AUX 1
Dosing pump flocculation
pH
APF
®
3
pH dosing pump
1
2
&

3. SYSTEM INSTALLATION

4
15
2
B
10
12
6
Paddle flow switch and temperature module
7
APF
®
dosing pump
8
pH dosing pump
9
pH injection
10
Prefilter
11
Wifi module
(see chapter 15)
12
APF
®
(not included)
13
pH-Minus
(not included)
14
If Outdoor pool: ACO
(not included)
15
Besgo valve
(not included)
4. ELECTRICAL CONNECTIONS
1
110-230 V
max. 3.15 A
2
1 2 3 4 5 6
1
2
3
4
5
6
7
8
1 2 3
AUX 2
Besgo backwash
4
&
valve
5
&
6
7
A
C
Variable Speed Pump
®
CONNECT ALL THE SENSORS CAREFULLY, A
BAD CONNECTION MAY CAUSE IRREPARABLE
DAMAGE TO THE DEVICE
DRY CONTACT
7 8 9
10 11 12 13 14
Free chlorine
3
4
red
black
N
L
A1 A2
14
11
12
FILTER PUMP
LIGHT
Filtration control
Lighting control
9
10
&
7
8
&
2
Electrical consumption
Use of a 13 Amp time delay circuit breaker is recommended
for private devices and a 16 A breaker for public devices.
In case of sharing the power supply with other devices
please consult a technician in order to dimension a correct
installation.
Maximum
Product
consumption
Product
DA-GEN 24
90 W
DA-GEN 240
DA-GEN 45
125 W
DA-GEN 360
DA-GEN 90
180 W
DA-GEN 500
DA-GEN 150
DA-GEN 750
175 W
Private
* Filtration control by external timer
Filtration mode:
AS Control 4
"Manual/ON"
230 V
* Filtration control by internal timer
Filtration mode:
Automatic
see Chapter 12
LINKS TO FILTER PUMP
230 V
1 2 3 4
Variable speed pump
1
1
3
2
3
Device control SLAVE
4
1
1
2
1
2
3
Connection ext. display*
3
Connection WIFI module
4
1
3
1
redoX
pH
AUX 3
AUX 4
ACO
®
Heating control
11
13
14
&
12
&
Maximum
consumption
680 W
1000 W
1020 W
2880 W
Public
slow
2
medium
fast
4
common
brown
2
blue
3
2
red
2
yellow
green
4
black
*IF connecting 2 displays on
the device, remember not to
connect the second display in
this communication channel.
Use the "ext. Display" socket
instead.
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dryden aqua

Table des Matières