ENGLISH
the appliance must first be switched off and disconnected from the electrical power supply.
• Connect the appliance to the electrical power supply/socket only if the rated power of the supply is compatible with the
maximum rated power of the appliance. If not, contact a professional electrician without delay.
• Switch off the system's main switch:
if an operating fault is detected;
before cleaning the outside of the appliance;
if the appliance is not going to be used for any length of time.
• The appliance cannot be used to pilot the operation of water
heaters, stoves, etc.; neither must it drain into the hot water
ducts of such appliances.
• The appliance must expel air directly to the outside through a
single dedicated duct.
• The flow of extracted air must be clean (i.e. free of grease,
soot, chemical and corrosive agents and explosive or
flammable mixtures).
• Keep the air intake and outlet ports of the appliance free of
obstructions, to ensure optimum air flow.
• Maximum operating temperature: 45°C.
• Specifications for the power supply must correspond to the
electrical data on ID plate A (Fig. 1).
An omnipolar switch with a contact opening
distance of 3 mm or higher should be provided for
installation, enabling complete disconnection
under overvoltage category III conditions.
Products equipped with three-phase wiring (T) engines ALWAYS require connection to 380-415V (or
only 400V where required) three-phase lines, or also 220-240V (or only 230V where required). Any
kind of modification shall be considered as product tampering and shall nullify the relative warranty.

Items supplied

2 2
B
A
Key to air connections (fig.2)
A: Clean air outlet inside the room
B: Stale air intake from room
C: Fresh air intake from outside
D: Stale air outlet to outside
16
1 1
The main parts of the appliance are:
• an outer casing made using galvanised steel;
• a polystyrene counterflow type heat exchanger, featuring a
C
special geometry designed to guarantee the highest
possible efficiency in terms of heat exchange (up to 94%);
• two energy-saving variable-speed brushless motors (3
preset speeds);
• an electronic controller supervising the power input,
regulation and control of the appliance;
• two thermal actuators controlling bypass valve opening
(only B.P. models);
• remote control panel;
• 3 temperature sensors;
• 2 x F5 filters;
• 4 brackets for ceiling application.