Check that the differential switch is in the OFF position. Do not place the differential switch
in the ON position until the Spa is full of water.
OFF
ON
049
Connecting the differential switch to the Kit
Before doing any work on the kit, the electrical power supply should be switched off
(differential switch in the OFF position, or disconnect the cable from the mains).
Use appropriate cable from the differential switch to the electrical cabinet of the kit,
depending on the type of location where the kit is to be installed, and current applicable
law. The cable section will be different depending on the model of kit and the distance of
the installation.
HIGH AMP / LOW AMP CONFIGURATION
Depending on the configuration of the kit, the consumption of electricity can vary
considerably, and as a result, the installation should match the electric power required.
LOW AMP
This configuration disconnects the electric heater when any massage pump is started-up.
This configuration limits the electricity consumption.
Note:
LOW AMP is the standard default configuration.
HIGH AMP
With this configuration, all the elements of the kit can operate at the same time. This
configuration uses a greater amount of electricity.
LOW AMP / HIGH AMP configurations can be changed using the switches on the electric
panel. The configuration options of the electric panel are shown further on in this Manual.
For High Amp you should put A2-A3-A4 in On position and A5 in Off position like the
picture below.
13