MAINTENANCE
WARNING! Turn off and unplug unit before cleaning or
servicing.
BEFORE EACH USE
Inspect Power Cord
Inspect power cord for cuts, fraying or damage; do not use if
damaged.
WEEKLY MAINTENANCE
Inspect Front Filter
Slide duct ring adapters for outlet D off to remove front filter for
cleaning. Slide out the filter and inspect for damage or
excessive dirt. Use a clean 3M™ HAF filter (see below).
Replace filter every four months or earlier if necessary. For
Parts and Service call your local distributor or the Dri-Eaz
Service Department at 800-932-3030 or 360-757-7776.
Use Clean 3M HAF Filters
Keep clean filters in the unit at all times to keep out dust and
protect internal components. HAF filters may be vacuumed
clean and reused up to three times before replacement.
Note: The two filters used for the unit are the same type but
different sizes. Be sure the appropriate size is installed.
MONTHLY MAINTENANCE
1.
Inspect Exterior
Inspect exterior components and make sure they are
properly installed. Listen to the unit for abnormal sounds.
For Parts and Service call your local distributor, or the Dri-
Eaz Service Department at 800-932-3030 or
360-757-7776
2.
Clean Exterior
Clean the housing with a damp cloth. Bring back the
original shine with a vinyl cleaner/polish like those used on
automobile plastics.
3.
Inspect Back Filters
The second set of filters is in the back of the unit on the
condenser side and may only require cleaning periodically
(every three to six months depending on the cleanliness of
the air ducted or drawn into the condenser inlet). To
access these filters, use a ⅜" socket wrench to remove
the six ¼-20 bolts holding the back cover and lower
handle in place. If you need further assistance, contact the
Dri-Eaz Service Department at 800-932-3030 or
360-757-7776.
07-01626B 2008-05
All manuals and user guides at all-guides.com
Copyright 2007 Dri-Eaz Products, Inc.
Back filters
Condenser Side Filter Location
SPECIFICATIONS
Model
Weight
Dimensions (H × D × W)
Amperage
Cooling Capacity
Capacity (@ 95°F/60% RH)
Air movement
Filters
Cord Length
Construction
Safety
Specifications are subject to change without notice. Some
values may be approximate.
ACCESSORIES
Ceiling Adapter Kit (F400)
The Ceiling Adapter Kit allows the user to direct the heat
absorbed by the EB1400 during A/C operation into a
suspended ceiling space and recirculate it back through the
EB1400. Isolating the heat dissipating stream from the cooling
stream creates a neutral air pressure environment, enabling
the EB1400 to deliver maximum cooling performance in
situations where it is not possible to vent absorbed heat
outside of the structure. Kit includes two lightweight ceiling
adapter housings, four 10 foot sections of semi-rigid ducting,
and a 24 × 24 in. cardboard panel to temporarily block ceiling
openings adjacent to adapter.
Rigid Performance® Ducting (F382)
One 10 ft. section of 8 in. diameter semi-rigid ducting.
LayFlat Ducting (F268)
One 500 ft. roll 8.3 in. (ID) x 4 mil poly layflat ducting.
FOR PARTS AND SERVICE CALL YOUR LOCAL DISTRIBUTOR
the Dri-Eaz Service Department at 800-932-3030 or
360-757-7776. www.dri-eaz.com
F388
195 lbs (88.5 kg)
49.5 × 33.5 × 27.25 in.
125.7 × 85.1 × 69.2 cm
11.7 amps
11,000 BTU/h
108 pints (51.1 liters)/day
470 CFM Evaporator air stream
750 CFM Condenser air stream
3M HAF filter
20 ft. (6.1 m)
Rotomolded shell
ETL listed to UL and CSA standards
or
4