ELECTRICAL CONNECTIONS

A
When making the wire connections, use the entire
length of conduit provided. The conduit must not
be shortened.
B
With the cooktop in place, open the front of the
cabinet door.
C
Insert the wires from the conduit through
the opening of the junction box.
The conduit strain relief clamp must be securely
attached to the junction box and the flexible conduit
must be securely attached to the clamp.
WARNING
Installations with Aluminum
House Wiring require attention. See Warning
under NOTES: ALUMINUM WIRING on page 2.
THREE-CONDUCTOR BRANCH
CIRCUIT CONNECTION
When connecting to a three-conductor branch circuit,
if local codes permit:
D
Connect the
cooktop green
ground con duc tor
lead to the
branch circuit
ground (green)
using a wire nut.
E
Connect the
cooktop red lead
to the branch
circuit red lead in ac cor dance with local codes,
using a wire nut.
F
Connect the cooktop black lead to the branch
circuit black lead in ac cor dance with local codes,
using a wire nut. If the residence red, black or
white leads are aluminum conductors, see
WARNING.
G
Install Junction Box Cover.
31-2001162 Rev. 1
Installation Instructions
Ground and
Neutral Wires
Junction Box Cover
NEW CONSTRUCTION AND BRANCH
CIRCUIT CONNECTION
• When installing in new construction, or
• When installing in a mobile home, or
• When installing in a recreational vehicle, or
• When local codes do not permit grounding through
neutral:
D
Attach the appliance grounding lead (green or
bare copper) in accordance with local codes. If
the residence grounding conductor is aluminum,
see WARNING.
Strain
Relief
E
Connect the red
and black leads
from the cooktop
conduit to the
corresponding
leads in the
junction box.
Connect the ground wire.
F
Once the connections are
made, secure wires together
using wire nuts.
G
Install Junction Box Cover.
Ground
Wire
Junction
Box Cover
Red
Strain
Relief
Clamp
Ground
Black
Black
Ground wire
location
Red
Strain
Relief
Clamp
Black
Ground
Red
7