Lighting The Fire; Adding Fuel / Heating At Nominal Thermal Output - HASE Merida Mode D'emploi

Masquer les pouces Voir aussi pour Merida:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

room is well-ventilated and open the windows
and outside doors. If needed, use a fan for
faster air circulation.
If the maximum temperature is not reached during the first he-
ating operation, you may notice an odour for a short period of
time the next time the stove is used as well.
7.
Lighting the Fire
The firing up phase should be as short as possible, since higher
emissions can occur during this phase.
The slider settings described in Table 1 (see figure on the right)
are recommendations that were determined under confor-
mance testing conditions, in compliance with the relevant stan-
dard. Depending on the weather conditions and the draught ca-
pability of your chimney, accordingly adjust the slider positions
for your Merida to the local conditions.
NOTE!
The Merida may only be operated when the fire
box door is closed; the fire box door may
only be opened to add fuel.
WARNING!
Never use spirits, petrol, or other flammable
fluids to light the stove.
36
Lighting the Fire
Procedure
Position of Control
Completely open primary
Pull primary and secondary air
and secondary air.
slider all the way out. (fig. 7)
Open fire grate.
Pull out fire grate slider.
Pile up any remaining ash
and unburned Charcoal
into the centre of the
combustion chamber.
Place 2-3 small logs into
Open fire box door.
the middle of the fire box;
stack approx. 0.5 kg of dry
wood chips on top.
Light the ignition material
Close fire box door.
at several places.
Tab. 1
(I)
(II)
Fig. 7
8. Adding Fuel / Heating at Nominal Thermal Output
More fuel should be added to the fire when the flames from the
Elements
previous burning off phase have just gone out.
Adding Fuel / Heating at Nominal Output
Procedure
Adjust primary and
secondary air.
Close fire grate.
Add two logs weighing approx.
0,8 kg in total. Place logs with
one end to the front of fire box.
Only add a single layer of fuel.
Tab. 2
Fig. 8
Position of
Control Elements
Close primary air slider
(I), set secondary air slider
(II) to position 3. (fig. 8)
Push in fire grate slider.
Open fire box door.
Close fire box door.
(I)
(II)

Publicité

Table des Matières
loading