Intended Use - DeVilbiss Healthcare 8650D Mode D'emploi

Compresseur grande puissance
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

c.
It has been dropped or damaged.
d.
It has been dropped into water.
Return the product to an authorized DeVilbiss service center for examination and repair.
5.
Keep the power cord away from heated surfaces.
6.
Never block the air openings of the product or place it on a soft surface, such as a bed or couch, where the air
openings may be blocked. Keep the air openings free of lint, hair, and the like.
7.
Never use while drowsy or asleep.
8.
Never drop or insert any object into any opening or hose.
9.
Do not use outdoors. This product is for indoor use only.
10. Do not use in an oxygen enriched environment.
11. Do not use this product with a DC to AC converter, or with any AC voltage and/or frequency other than specified.
12. Do not operate unit in a backpack or carrying bag.
13. Care should be taken when this product is used in the vicinity of other electronic equipment concerning the possible
interference between them. They may need to be moved apart.
14. Use caution when plugging in and unplugging device. Do not allow jewelry or other metal items to contact plug.
15. Warning: This product contains small parts that may represent a choking hazard.
save tHese INstruCtIoNs

INteNDeD use

The DeVilbiss 8650D is used with a pneumatic nebulizer to administer humidified air or medication into the airways to treat
respiratory disorders. The device is intended for home health care and institutional use. Users of this device are adult and
pediatric patients with tracheostomies or suffer from asthma, cystic fibrosis, and chronic obstructive pulmonary disease.
NotE—The DeVilbiss 8650D is to be used only when prescribed by a physician and operated in accordance with this
guide.
8650D ImportaNt parts (page eN-2)
Figure a
1.
Pressure gauge
2.
Power switch
3.
Pressure adjustment knob
4.
Air outlet
5.
Extension tube (optional 8650D-613)
6.
Tubing connector (optional CN100)
8650D Compressor operatIoN
1.
Make sure the power cord is unplugged from wall-outlet power source.
WarNING
Explosion Hazard. Do not operate in the presence of flammable anesthetics.
2.
Refer to Important Parts of Your 8650D Compressor for part identification.
3.
Place the 8650D compressor on a flat surface in a position allowing for adequate air flow from the rear of the device.
CAutIoN—During high-humidity weather conditions, condensation water build-up can occur in the internal motor hose of
the compressor. It is recommended that the 8650D be turned on and run for two minutes before the nebulizer/tubing is
connected to the compressor.
4.
For disposable nebulizer use, thread the optional tubing connector to either the compressor air outlet or optional
extension tube, then attach one end of nebulizer tubing Figure 1 or Figure 2.
NotE— F ollowspecificinstructionsprovidedbyphysicianforsetupofbothnebulizerandmedication.
5.
For high output humidification, thread the bottle adapter directly to the extension tube air outlet Figure 3.
6.
Before plugging in the power cord, make sure the power switch is in the "Off" position by pressing on the bottom half
of the switch Figure 4. Plug the power cord into a properly grounded wall-outlet power source.
eN - 4
Figure B
1.
Fan filter
2.
Power connector/Fuse holder
A-703

Publicité

Chapitres

Table des Matières
loading

Table des Matières