Dri-Eaz DrizAir 1200 Manuel Du Propriétaire page 7

Masquer les pouces Voir aussi pour DrizAir 1200:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

T
ROUBLESHOOTING
For any problems not listed below, call your local distributor or contact our Service Department toll free at 888-867-3235.
PROBLEM
Unit does not operate
Compressor will not start
Blower wheel not turning
Unit operating, but room not dry
Unit continuously in defrost
Unit collects little water
Pump does not function
S
PECIFICATIONS
DrizAir
1200
DrizAir
2000
DrizAir
2400
07-01486 A 04-04 Copyright 2004 Dri-Eaz Products, Inc.
CAUSE
No power to machine
Switch not turned on
Unit needs 5 minutes before restart
Overload preventing start up
Obstructed blower
Loose blower wheel set screw
Not enough time to dry
Poor air movement in room
Excessive air infiltration
Room temperature too low
Room air is dry
Room temperature too low
Airflow through unit restricted
Stuck float valve
MODEL
DRIZAIR 1200, F203
TYPE
STANDARD REFRIGERANT HOUR METER
HEIGHT
32" (83 CM)
WIDTH
20" (50 CM)
DEPTH
19.5" (50 CM)
USE WEIGHT
80 LB (36 KG)
WATER REMOVAL MAX
123 PT/DAY (58 L)
WATER REMOVAL AHAM 64 PT/DAY (30 L)
OPERATING RANGE
33° - 100° F (1° - 38° C)
COMPRESSOR TYPE
6,670 BTU ROTARY
DEFROST TYPE
HOT-GAS BYPASS
PROCESS AIR
227 CFM (386 CMH)
MODEL
DRIZAIR 2000 , F232
TYPE
LOW GRAIN REFRIGERANT HOUR METER
HEIGHT
40.5" (103 CM)
WIDTH
24" (50 CM)
DEPTH
22.5" (57 CM)
USE WEIGHT
132 LB (60 KG)
WATER REMOVAL MAX
224PT/DAY (106 L)
WATER REMOVAL AHAM 112 PT/DAY (53 L)
OPERATING RANGE
33° - 100° F (1° - 38° C)
COMPRESSOR TYPE
10,120 BTU ROTARY
DEFROST TYPE
HOT-GAS BYPASS
PROCESS AIR
360 CFM (611 CMH)
MODEL
DRIZAIR 2400, F246
TYPE
LOW GRAIN REFRIGERANT HOUR METER
HEIGHT
47" (119 CM)
WIDTH
24" (61 CM)
DEPTH
27" (69 CM)
USE WEIGHT
162 LB (73 KG)
WATER REMOVAL MAX
240 PT/DAY (114 L)
WATER REMOVAL AHAM 148 PT/DAY (70 L)
OPERATING RANGE
33° - 100° F (1° - 38° C)
COMPRESSOR TYPE
13,315 BTU ROTARY
DEFROST TYPE
HOT-GAS BYPASS
PROCESS AIR
360 CFM (611 CMH)
SSSOLUTION
Plug in the unit; check power at outlet.
Turn on switch.
Switch off unit, wait 5 minutes before starting.
Reduce room temperature below 90°F (32°C).
Remove obstruction.
Tighten Screw.
Allow more time for drying.
Increase airmovement with TurboDryers.
Reduce airflow into the area being dried.
Increase room temperature.
Check humidity with hygrometer.
Increase the room temperature.
Check filter and coils, clean if debris.
Clean float valve shaft.
CONTROLS
WATER PUMP-OUT
DRAIN HOSE LENGTH 40 FT (12.2 M)
AIR FILTER
WHEELS
HANDLE
HOUSING
POWER 115V
CORD LENGTH
SAFETY MARKS
CONTROLS
WATER PUMP-OUT
DRAIN HOSE LENGTH 40 FT (12.2 M)
AIR FILTER
WHEELS
HANDLE
HOUSING
POWER 115V
CORD LENGTH
SAFETY MARKS
CONTROLS
WATER PUMP-OUT
DRAIN HOSE LENGTH 40 FT (12.2 M)
AIR FILTER
WHEELS
HANDLE
HOUSING
POWER 115V
CORD LENGTH
SAFETY MARKS
TOUCHPAD
YES
CENTRIFUGAL
3M™ HIGH AIRFLOW*
SEMI-PNEUMATIC
TELESCOPING
ROTOMOLDED
6.4 AMPS
25 FT (7.6 M)
UL, C-UL
TOUCHPAD
YES
CENTRIFUGAL
3M™ HIGH AIRFLOW*
SEMI-PNEUMATIC
FIXED METAL
ROTOMOLDED
8 AMPS
25 FT (7.6 M)
UL, C-UL
TOUCHPAD
YES
CENTRIFUGAL
3M™ HIGH AIRFLOW*
SEMI-PNEUMATIC
ROTOMOLD./METAL
ROTOMOLDED
11 AMPS
25 FT (7.6 M)
UL, C-UL
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Drizair 2000Drizair 2400

Table des Matières