TRMS Multimeter
Note: Accuracy specifications consist of two elements:
(%reading)–This is the accuracy of the measurement circuit.
(+digits)–This is the accuracy of the analog to digital converter.
Enclosure
Shock(Drop Test)
Diode Test
Continuity Check
Temperature Sensor
Input Impedance
AC Response
ACV Bandwidth
Crest Factor
Display
Overrange indication
Auto Power Off
Polarity
Measurement Rate
Low Battery Indication
110
Double molded
6.5 feet(2 meters)
Test current of 1.5mA maximum, open circuit voltage 3V
DC typical
Audible signal will sound if the resistance is less than 50Ω
(approx.), test current <0.35mA
Requires type K thermocouple
>10M V DC & >10M V AC
TRMS
50/60HZ(ALL WAVE)45Hz to 1000Hz(SINE WAVE)
≤3 at full scale up to 300V, decreasing linearly to
≤1.5 at 600V
4,000 counts LCD Negativity display
"OL" is displayed
15 minutes(approximately)with disable feature
Automatic(no indication for positive); Minus(-)sign for
negative
3 times per second, nominal
" " is displayed if battery voltage drops below
operating voltage