6.2.1 Description du registre

Type
R/W
R/W
R
R/W
R/W
R
R/W
R
R/W
R/W
R/W
R
R/W
R/W
UG_ARF73 V1.7
All manuals and user guides at all-guides.com
Register
Function
Radio management
S200
Channel table
S201
Channel number Select radio channel from
S204
Preamble dura-
tion
S217
Serial Time out
for radio
S218
Radio frame
length
S230
RSSI level
S231
RF out level
S238
Receiver Fre-
quency BW
S220
Over the air
format
S252
Reception
address
S256
Transmission
address
S254
RF link speed
S255
Squelch
S257
CSMA mode
Description
Set channel table
the table:
From 0 up to 15
Preamble duration unit in
ms.
Serial timeout before star-
ting radio transmission, unit
ms. From 4 up to 240
Size of the radio frame (from
1 up to 240).
When this size is reached:
the transceiver sends a
radio frame
Display the reception level
of the latest received mes-
sage. Response S230=-
xxxdBm<cr><lf> (with xxx
decimal value)
Adjust the RF output level
0-> 500mW (27dBm)
1-> 1W
(30dBm)
2-> 2W
(33dBm)
3 -> 4W
(36dBm)
Indicates the bandwidth
adjustment of the helicoidal
receiverfilters.
Format is 438.5000
0 -> addressed mode
1 -> transparent mode
2 -> repeater mode
From 0 up to 255
Used in addressed and
repeater protocol only, for
filteringincomingframe
From 0 up to 255
Used in addressed protocol
only, added to out coming
frame
1 -> 4800 bps
2 -> 9600 bps
0 -> max product sensitivity
1 -> about -107dBm
2 -> about -100dBm
3 -> about -70dBm
0 -> disable
1 -> enabled
Frame is not transmitted
and silently discard if S258
threshold is reached
Default Value
Note
-
8
25
4
3
none
3
Depending
on customer
demand
0
0
0
2
0
0
15