Connector System For Connecting Solar Panels - Samlex Solar SRV-100-30A Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SECTION 3 |
The Positive (+) wire of the solar panel is terminated with a MC4 Female Connector (marked +). Connect
this to the MC4 Male Connector (marked -) that is attached to the Positive PV Extension Wire. Make sure
that the locking tabs "snap in" for a firm connection. The bare end of the Positive extension Wire will
now be of Positive polarity. Use a piece of red sleeve or red tape near the bare end for identification as
the Positive (+) wire.
The Negative (-) wire of the solar panel is terminated with a MC4 Male Connector (marked -). Connect this to
the MC4 Female Connector (marked +) that is attached to the Negative extension wire. Make sure that the
locking tabs "snap in" for a firm connection. The bare end of the Negative PV Extension Wire will now be of
Negative polarity.
Connect the two PV Extension Wires to the Charge Controller.
WARNING!
Ensure that the polarity (+ or -) of the wires is identified correctly before connecting to the Charge
Controller. Damage due to wrong polarity may not be covered under warranty.
Connecting Second Adjacent Solar Panel in Parallel (Fig. 3.4)

Connector System for Connecting Solar Panels

Fig. 3.4. Connecting two adjacent solar panels in parallel
SBC-2 Kit
MC4 female
branch connector (-)
MC4 male
branch connector (+)
SAMLEX AMERICA INC. | 9
SCW-20-2 Kit
To external
PV circuit