DV210 - (7,10)SG
Conversion Kit Part Number 17080
This conversion kit is to be installed by an Empire Comfort Systems, Inc. distribu tor (or other qualified
agency
)* in accordance with the manufac turer's instruc tions and all codes and requirements of the
1
authority having jurisdiction. Failure to follow instructions could result in serious injury or property
damage. The qualified agency performing this work assumes responsibility for this conversion.
National Fuel Gas Code Z223.1 (Latest Edition) Natural Gas and Propane Installation Code, CSA B149.1
1
*The term "qualified agency" means any individual, firm, corporation or company which either in
person or through a representative is engaged in and is responsi ble for (a) the installation of gas
piping or (b) the connection, installation repair, or servicing of equipment, who is experienced
in such work, familiar with all precau tions required, and has complied with all the requirements
of the authority having jurisdic tion.
Robertshaw gas valves with production dates beginning with code 0306 and ending with 0436 are
subject to a Robertshaw Controls Company voluntary recall. Do not convert valves in this date
code range. Valves that have been repaired can be converted. Call the Robertshaw recall hotline
at 1(800) 232-9389 or visit www.robertshaw.com.
The date code on the valve label is next to a small diamond shape with the letter "X" inside it.
Installer: Use Robertshaw
regulator section on
Robertshaw valves and
Dexen regulator section
on all other valves.
Perform the safety shutdown test any time work is done on a gas system to avoid the possibility
of fire or explosion with property damage, personal injury or loss of life.
SAFETY SHUTDOWN SYSTEM
Continuous Ignition Systems
1. Place gas control knob in PILOT position. Main burner should go off and pilot should remain lit.
2. Extinguish pilot flame. Pilot gas flow should stop within 3 minutes. Safety shut-off of pilot gas proves complete shutdown
since safety shut-off valve blocks flow of gas to main burner and pilot.
3. Relight pilot burner and operate system through one complete cycle to make sure all controls operate properly.
17112-5-0819
GAS CONVERSION INSTRUCTIONS
DIRECT - VENT WALL FURNACES
FOR USE ON DIRECT - VENT WALL FURNACE MODELS
CONVERSION KITS
DV210SGX - 1,2
FOR CONVERSION TO PROPANE GAS
ROBERTSHAW VALVE
CHECK SAFETY SHUTDOWN PERFORMANCE
DV215 - (7,10)SG
Conversion Kit Part Number 17082
WARNING
WARNING
NON-ROBERTSHAW VALVE
WARNING
DV215SGX - 1,2

Publicité

loading

Sommaire des Matières pour Empire Comfort Systems DV210-SG

  • Page 1 FOR CONVERSION TO PROPANE GAS WARNING This conversion kit is to be installed by an Empire Comfort Systems, Inc. distribu tor (or other qualified agency )* in accordance with the manufac turer’s instruc tions and all codes and requirements of the authority having jurisdiction.
  • Page 2 PARTS LIST Kit Number 17080 Kit Number 17082 Part Quantity DV210-(7,10)SG DV215-(7,10)SG Description Supplied DV210SGX-1,2 DV215SGX-1,2 Pilot Orifice R-1089 R-1089 Main Burner Orifice P-8665 P-8658 10" w.c. Regulator R-1086 R-1086 Dexen 10" w.c. Regulator R-7548 R-7548 1/4" Copper Pilot Tubing 40994 40994 with Ferrells Conversion Label R-1322 R-1322 Gas Conversion Label R-1321 R-1321 GAS INPUT FOR DIRECT VENT WALL FURNACE...
  • Page 3 POUR LA CONVERSION EN GAZ PROPANE AVERTISSEMENT CCet ensemble de conversion doit être installé par un distributeur d’Empire Comfort Systems, Inc. (o une autre agence qualifiée 1)* conformément selon les instructions du fabricant et selon tous les codes et exigences des autorités ayant juridiction. De sérieuses blessures ou des dommages à...
  • Page 4 LISTE DES PIÈCES Numéro de Numéro de Description l'Ensemble 17080 l'Ensemble 17082 Quantité des Pièces DV210-(7,10)SG DV215-(7,10)SG Fournie DV210SGX-1,2 DV215SGX-1,2 Pilot Orifice R-1089 R-1089 Main Burner Orifice P-8665 P-8658 10" w.c. Regulator R-1086 R-1086 Dexen 10" w.c. Regulator R-7548 R-7548 1/4" Pilot Tubing 40994 40994 with Ferrells Conversion Label R-1322 R-1322 Gas Conversion Label R-1321...

Ce manuel est également adapté pour:

Dv210-7sgDv210-10sgDv210sgx-1Dv210sgx-2Dv215-sgDv215-7sg ... Afficher tout