Difference Hold Mode; Measured Value Hold Mode - Balluff BOD 26K LB04-S115-C Instructions De Service Et De Montage

Masquer les pouces Voir aussi pour BOD 26K LB04-S115-C:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Mounting and
operating instructions

Difference hold mode

When the difference hold function is activated and Q
mum and maximum value of the measuring signal and stores it.
If Q
= -U
, the last differential value is transmitted at the analogue output.
1
B
Example of use: Checking the contents of open containers or packages.
100% (20 mA)
0% (4 mA)
100% (20 mA)
0% (4 mA)
+U
B
Q
1
-U
B
B
Illustr. 18

Measured value hold mode

When this function is activated, the last valid measured value is saved.
When no object is in the measuring range, the last valid measured value is transmitted at the analogue output. The
current value is only displayed again when an object is within the measuring range (OK LED = on).
Example of use: Maintain position of tool during change-over of work piece when machining.
Behaviour of analogue output with and without measured value hold.
Start of measuring range
End of measuring range
100% (20 mA)
100% (20 mA)
0% (4 mA)
0% (4 mA)
100% (20 mA)
100% (20 mA)
0% (4 mA)
0% (4 mA)
ON
Good Target Q
ON
2
OFF
Good Target Q
2
OFF
Illustr. 19
No. 834826 E Edition 1111; Replaces edition 0901; Subject to modification
2
1
1
B
A
A
With measured value hold
Without measured value hold
t(s)
= +U
, this function detects the difference between the mini-
1
B
12 mA
1
2
2 mA
2
Q
= +U
A
1
B
Q
= -U
1
B
= Sample. Collect measured values
B
= Display. Last maximum of analogue signal at
B
analogue output
37