Mounting and
operating instructions
No. LED pattern Description
13
Switches off averaging.
The first measured value is taken into
account (page 35).
14
Switches on 4 ms averaging: the first
10 meas. values are taken into account
(page 35).
15
Switches on 40 ms averaging: all
(max. 100) meas. values are taken into
account (page 35).
16
Set analogue output 0% (4 mA). When
S button is activated, the current meas.
value corresponds with 0% value of the
analogue output.
17
Set analogue output 100% (20 mA).
When S button is activated, the current
meas. value corresponds with 100%
value of the analogue output.
18
Q
autom. zero input mode: characte-
1
ristic curve displacement. If Q
the current measuring signal is set to
the analogue value 0 % = 4 mA. The
incline of the characteristic curve is
maintained. If exceeded, the characteri-
stic curve ends at the start or end of the
measuring range.
19
Q
autom. centre input mode: displace-
1
ment of centre of characteristic curve. If
Q
= +U
1
is set to the analogue value
50 % = 12 mA. The incline of the cha-
racteristic curve is maintained. If excee-
ded, the characteristic curve ends at the
start or end of the measuring range.
20
Q
maximum hold mode: Provided
1
Q
= +U
1
value is stored.
If Q
1
transmitted at the analogue output. A
minimum hold can be set by inverting
the analogue characteristic curve (ana-
logue 100% point < analogue
0 % point).
21
Q
difference hold mode:Provided
1
Q
= +U
1
measured values is saved. When Q
-U
, the determined value is transmitted
B
at the analogue output.
* as long as the S button is pressed
No. 834826 E Edition 1111; Replaces edition 0901; Subject to modification
, the current measuring signal
B
, the max. recorded measured
B
= -U
, the determined value is
B
, the difference between the
B
"ZA" status indicator
On = Averaging off
On = active
Off = not active
On = active
Off = not active
On* = Object within...
Off* = Object outside...
...measuring range
On* = Object within...
Off* = Object outside...
...measuring range
On = Autom. zero input active
= +U
,
Off = Autom. zero input not active
1
B
On = Autom. centre input active
Off = Autom. centre input not
active
On = Maximum hold active
Off = Maximum hold not active
On = Difference hold active
Off = Difference hold not active
=
1
Factory setting
On
Off
Off
0% = 4 mA = end of
meas. range
100% = 20 mA =
start of meas. range
Not active
Not active
Not active
Not active
33