Maintenance; Lubrication; Vent; Service And Parts Information - Vulcan VGCTS16 Manuel D'installation Et D'utilisation

Table des Matières

Publicité

The tilting braising pan and its parts are hot. Use care when operating, cleaning
or servicing the braising pan.
Disconnect the electrical power to the machine and follow lockout / tagout procedures
before performing any maintenance.

LUBRICATION

Never grease or oil the pivot bearings as this may cause problems with tilting. Bearings are oilite and
never require lubrication.

VENT

Periodically check the flue, when the braising pan is turned off and is cool, to be sure it is free of obstructions.

SERVICE AND PARTS INFORMATION

To obtain service and parts information concerning this unit, contact the Vulcan Service Agency in your
area, or visit www.vulcanequipment.com.
Problem
Burners do not come on.
Braising pan difficult to tilt.
FORM 31041 Rev. A (May 2018)
All manuals and user guides at all-guides.com

MAINTENANCE

TROUBLESHOOTING

Possible Cause
1. The power supply is off.
2. The gas supply to the braising pan is off.
3. The gas valve is off.
4. The thermostat is not turned on.
5. The pan is not in the lowest position.
6. Problem with the gas control system. Contact your Vulcan
authorized servicer.
1. Dirt in oilite bearings causing it to bind. Call your local Vulcan-
authorized servicer.