Nibe RMU S40 Manuel D'installation page 25

Masquer les pouces Voir aussi pour RMU S40:
Table des Matières
Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 54
TIP
Wait 24 hours before making a new setting,
so that the room temperature has time to sta-
bilise.
If it is cold outdoors and the room temperature
is too low, increase the curve slope in menu
1.30.1 by one increment.
If it is cold outdoors and the room temperature
is too high, reduce the curve slope in menu
1.30.1 by one increment.
If it is warm outdoors and the room temperat-
ure is too low, increase the value in menu 1.1.1
by one increment.
If it is warm outdoors and the room temperat-
ure is too high, reduce the value in menu 1.1.1
by one increment.
HOT WATER
When there is a temporary increase in hot water de-
mand, this menu can be used to select an increase in
the hot water temperature for a selectable time.
You can also select "More hot water" in the main
product's menu 2.1.
VENTILATION
The ventilation in the accommodation can be temporarily
increased or reduced here.
The return time for the fan may, if necessary, be
changed in the main product's menu 1.2.5 – "Fan return
time".
POOL
Here you can change the temperature of the water in
the pool or activate/deactivate heating.
PV SOLAR
You can read off the value of the power that the solar
panels are currently providing.
You can also see how many kWh the solar panels have
produced during the current calendar month.
HOME/AWAY
Here you can activate or deactivate the "Away mode"
function.
The function is activated if you select "Away" when you
leave your home. In order to deactivate, select "Home".
The settings for "Away mode" are made in the main
product's menu 4.5 "Away mode".
NIBE RMU S40 | GB
MENU 1 – NIGHT MODE
NIGHT MODE
Setting: On/Off
SCHEDULE NIGHT MODE
Setting: 00.00 – 23.59
You can activate night mode here.
Activate night mode during the time of day you want to
switch off the backlight.
MENU 2 – CONNECTIONS
Select wireless or wired connection.
WIRELESS CONNECTION
Select wireless connection.
Go to the main product and select menu 5.4 – "Connect
wireless units".
WIRED CONNECTION
Select a communication address for RMU S40 by alloc-
ating it a unique number in this menu.
Setting: 1 – 8
MENU 4 – LICENCES
You can find licences for open source code here.
MENU 7 – DISPLAY ZONES
Here, you can select the zones that you want to be dis-
played in your RMU S40, for heating and cooling.
You can choose to display a maximum of ten zones.
MENU 8 – FACTORY SETTING
Reset to factory setting.
MENU 9 – INFORMATION
Here, information is displayed about the product and
the software version that is installed.
Caution
You can choose to control your main product
according to the moisture content (RH) in the
air, which is measured by your RMU S40. Ac-
tivate this choice in menu 7.1.6.4 – "Humidity
control" in the main product.
You can also choose to control your main
product according to the relative humidity (RH)
in the air during cooling operation. (If you have
cooling installed and activated.) Activate this
choice in menu 7.1.7.2 – "Humidity control" in
the main product. Select "Limit RH in cold"
25