Connections, Operating And Display Elements; Oled Display - Cameo F4 D PO IP Manuel D'utilisation

Masquer les pouces Voir aussi pour F4 D PO IP:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25

CONNECTIONS, OPERATING AND DISPLAY ELEMENTS

5
1
POWER IN
TRUE1 compatible mains input socket. Operating voltage 100–240 V AC/50–60 Hz. A suitable power cable with powerCON IP65 plug is
included in delivery. Always blanked with the corresponding rubber blanking cap if not used.
2
POWER OUT
TRUE1 compatible mains output socket for power supply to additional CAMEO spotlights. Ensure that the total current consumption of
all connected devices does not exceed the value specified on the device in amperes (A). Always blanked with the corresponding rubber
blanking cap if not used.
DMX IN
3
Male IP65 5-pin XLR connector to connect a DMX control device (e.g., DMX console). Always blanked with the corresponding rubber
blanking cap if not used.
DMX OUT
4
Female IP65 5-pin XLR connector to transmit the DMX control signal. Always blanked with the corresponding rubber blanking cap if not used.

OLED DISPLAY

5
Displays currently active mode and the menu items in the Edit menu.
DIM/MENU
6
Rotary-push encoder for the adjustment and control of the spotlight.
DIM – If one of the DMX modes is enabled and there is no DMX signal to the device, the encoder serves as master dimmer control and you
can set the brightness of the spotlight with values from 000 to 255 by turning the encoder (Quicklight).
Quicklight
000-255
MENU – Push the encoder to access the main menu and select menu items by turning the encoder.
---------------- Menu ----------------
DMX Address
DMX mode
Stand Alone
Slave
Settings
System Info
7
6
1
2
3
4
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

F4 t po ipClf4dpoipClf4tpoip

Table des Matières