Be careful not to damage the seals when repositioning the cover onto the actuator body.
Tighten each cover screw.
For the Exd or EEx d versions, screws of explosion-proof actuator body must be of a minimum
8.8 quality grade unless otherwise stated.
Ensure that the cable glands are conforming to the explosion-proof equipment standards and
to the Ex classification.
Check that cable glands are used and wiring done according to the explosion-proof equipment standards ;
take a special care of the compatibility between the cable diameter and the cable gland size.
If one of the cable entries is not used, seal it with a certified metal plug and without adapter. Metal
plug with EExd like EExdIIC Capri type B or ATX type ACC.
A connection to the earth (4mm2 or 6mm2 following the model) has to be wired using the actuator
external grounding plug. Internal and external groundings have to be connected together.
The EEx ed actuators single phase motors are supplied with a separate capacitor. This capacitor
must not be fitted, in any case into the actuator. It has to be installed in a safe area, for example, at
the outlet of the motor power supply contactors.
The EEx ed actuators motors wire must be connected directly to the motor specific connection
box. The motor wire must not go through the actuator end of travel connection box unless agreed
by BERNARD CONTROLS.

3 OPERATION

Do not open the cover when an explosive atmosphere may be present. Never leave the cover open,
in order to avoid any risk of water inlet.
INTELLI+ VERSION CAUTION
Respect the actuator duty cycle indicated
Never use the Intellisoft infrared
on the identification plate. For example, for a 30%
communication kit in an explosive area.
duty and a 40s operating time, the minimum time
This module is not explosion-proof.
between two operations is 93 s. In case of over-
In explosive areas, set-up the actuator
heating, the thermal protection will disrupt the
only by using the local control buttons.
motor power supply in order to limit the actuator
body temperature elevation.
In case of use in explosive dust atmosphere, check that cover tightness joints are intact and make
sure not to degrade the joints while closing the cover.