Chauvin Arnoux Multimetrix CM 605 Notice De Fonctionnement page 14

Multimètre
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
7.3 TO MEASURE VOLTAGE
Please read the safety recommendations before use.
Automatic measurement ranges 600V DC or AC.
1.
Set the selector (8) on:
-
to measure a DC voltage.
-
to measure an AC voltage.
2.
Insert the black connector into the COM terminal (1), the red
connector into the + terminal (10) and take the voltage reading
once it has stabilised.
When the AUTO icon (23) is displayed, the multimeter determines
the optimum measurement range.
For a continuous voltage, the icon « - » (rep. 11) indicates reversal of
the contact points' polarity.
« OL »" indicates that the capacity has been exceeded.
To display the peak value (PEAK), see § 7.9.
To freeze the read value, (DATA HOLD), see § 7.10.
3.
Set the selector to OFF.
7.4 TO MEASURE DC CURRENT
Please read the safety recommendations before use.
Automatic measurement ranges from 10 A DC to 100 A DC (3 ranges).
1.
Set the selector (8) to
2.
Press the ZERO button (9) to set zero.
The icon
subsequent measurement. Press this button again to exit the zero
mode.
3.
Press the trigger (3) to open the clamp (5) and position the
conductor in the centre of the clamp (Fig. 3).
NB: never insert two + and – conductors from the same circuit in the
clamp; the reading will be zero.
4.
Take the current reading once it has stabilised.
When AUTO (rep. 15) is displayed, the multimeter determines the
optimum measurement range.
The icon « - » (rep. 11) indicates reversal of the contact points'
polarity ; refer to the « + » mark graven on the clamp (rep. 6).
If « OL » is displayed, the capacity has been exceeded.
To display the peak value (PEAK), see § 7.9.
To freeze the read value, (DATA HOLD), see § 7.10.
5.
Open the clamp, release the conductor and set the selector to
OFF.
7.5 TO MEASURE THE AC CURRENT
Automatic measurement ranges from 10 A AC to 100 A AC (3 ranges).
1.
Set the selector (8) to
2.
Press the trigger (3) to open the clamp (6) and position a
conductor in the centre of the clamp (Fig. 3).
NB: never insert two conductors from the same circuit in the clamp;
the reading will be zero.
3.
Take the current reading once it has stabilised.
The AUTO icon (15) is displayed; the multimeter determines the
optimum measurement range.
If "OL" is displayed, the capacity has been exceeded.
To display the peak value (PEAK), see § 7.9.
To freeze the read value, (DATA HOLD), see § 7.10.
4.
Open the clamp, release the conductor and set the selector to
OFF.
7.6 TO MEASURE THE RESISTANCE
Please read the safety recommendations before use.
There must be no voltage in the circuit.
Automatic measurement ranges from 0 to 10KΩ (1 range).
1.
Set the selector (8) to
2.
Insert the black connector into the COM terminal (1), the red
connector into the + terminal (10) and take the reading.
If OL is displayed, the capacity has been exceeded.
When AUTO (rep. 15) is displayed, the multimeter determines the
optimum measurement range.
3.
Set the selector to OFF.
.
is displayed; the reading is stored as reference value for
.
.
14