BATTERY SOC DISPLAY
When the battery voltage is indicated as low, it is recommended to use the remaining energy economically.
The charge controller will subsequently turn off the load.
OK (Yellow LED off) Battery voltage > 12V
Low (Yellow LED off) 12V > Battery voltage > 11.5V
Very Low (Yellow LED flashes) 11.5V > Battery voltage > 11V
LOAD STATUS DISPLAY
In case of deep discharge or overload/short circuit of load, the load output is switched off. This is indicated by:

5. INSTALLATION INSTRUCTIONS

BEFORE YOU BEGIN
The controller is intended for indoor use only.
Note
Protect the controller from direct sunlight and place it in a dry environment.
The controller and battery must be installed in the same room.
The controller warms up during operation; be sure it is installed on a non-flammable surface.
CONNECT THE CONTROLLER
Please verify that all the cable/wire connections are made properly and well insulated so that no water or humidity can get in.
This avoids any bad or loose connections that would result in excessive heating or further damage.
1. *Connect the battery to the charge controller; Positive (+) & Negative (-).
2. Connect the solar modules to the charge controller; Positive (+) & Negative (-).
3. Connect the load to the charge controller; Positive (+) & Negative (-).
*Go Power! strongly recommends installing an inline fuse as close to the battery terminal as possible.
See illustrated steps on the following page.
[page 6] | gpelectric.com
Normal operation (Red LED off)
Low/high voltage disconnect (Red LED on)
Overload or short circuit of load (Red LED flashes)
5. INSTALLATION INSTRUCTIONS