2. Pour condensed water out into a basin
or similar receptacle.
3. Slide outlet connections in and refit wa-
ter reservoir.
If the programme has been interrupted
as a result of the water reservoir being
full: Push the START PAUSE button to
continue the drying cycle.
The water from the water reservoir can be
used as distilled water, e.g. for steam iron-
ing. But first filter the water (e.g. with a coffee filter) to remove residue and small pieces
of the fluff.

Cleaning heat exchanger filters

If the indicator clean base filters
of the appliance must be cleaned, i.e. after each 3 drying cycles. Both filters are located
in the appliance base.
Water can collect in the filter housing therefore it is normal for the heat exchanger fluff
filters to become wet.
• Do not operate the tumble dryer without the fluff filters.
• Clogged filters cause higher energy consumption (drying cycle elongation) and tumble
dryer damage.
• A dirty heat pump can only be cleaned up with a costly process.
1. Open loading door
2. Open door in plinth: To do this, push the
release button on the bottom of the
door aperture and open the door in the
plinth to the left.
3. Pull filter housing out of the base by the
handle.
All manuals and user guides at all-guides.com
lights up, the heat exchanger fluff filters in the base