Add Engine Oil; Check Pump Oil (Triplex Units); Fuel - Generac Small Pro Manuel Du Propriétaire

Masquer les pouces Voir aussi pour Small Pro:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

General Information and Setup
4. See
Figure
2-4. Attach siphon tube to
siphon tube outlet (A).
A
Figure 2-4. Attach Siphon Tube

Add Engine Oil

Unit is shipped with no oil in the
crankcase. Add engine oil before starting.
See
Engine Oil
Recommendations.
1. Place power washer on a level surface.
2. Verify oil fill area is clean.
3. Remove oil fill cap and wipe dipstick clean.
Figure 2-5. Remove Dipstick
4. Add recommended engine oil.
NOTE: Some units have more than one oil fill
location. It is only necessary to use one oil fill
point.
5. Thread dipstick into oil filler neck. Oil level
is checked with dipstick fully inserted.
6. See
Figure
2-6. Remove dipstick and verify
oil level is within safe operating range.
Figure 2-6. Safe Operating Range
7. Install oil fill cap/dipstick and hand-tighten.

Check Pump Oil (Triplex Units)

NOTE: The axial cam and Cat pumps are
maintenance free and do not require checking
oil.
1. Place power washer on a flat, level
surface.
4
A
A
001537
000115
000116
2. See
Figure
2-7. Clean area around oil fill
and remove vented cap/dipstick (A).
A
Figure 2-7. Check Pump Oil
3. See
Figure
2-8. Check to confirm oil level
is between the "L" and "H" on the dipstick
when breather is screwed in. If oil is
required, see
Pump Oil (Triplex
NOT OVERFILL.
4. Install oil dipstick until finger tight.
5. Clean up any spilled oil.
Figure 2-8. Pump Oil Dipstick

Fuel

DANGER
Explosion and Fire. Fuel and vapors are extremely
flammable and explosive. Add fuel in a well
ventilated area. Keep fire and spark away. Failure
to do so will result in death or serious injury.
Fuel requirements are as follows:
• Clean, fresh, unleaded gasoline.
• Minimum rating of 87 octane/87 AKI (91
RON).
• Up to 10% ethanol (gasohol) is acceptable
(non-ethanol fuel is recommended where
available).
• DO NOT use E85.
• DO NOT use a gas oil mix.
• DO NOT modify engine to run on alternate
fuels.
• Add a fuel stabilizer prior to storing.
1. Verify unit is OFF and cooled for a
minimum of two minutes prior to fueling.
2. Place unit on level ground in a well
ventilated area.
3. See
Figure
2-9. Clean area around fuel
cap and remove cap slowly.
4. Slowly add recommended fuel. Do not
overfill
Owner's Manual for Power Washer
001539
Units). DO
H
L
000268
(000105)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

G0069240