AEG WSP 2010 Notice D'utilisation Et De Montage page 20

Accumulateurs de chaleur
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

For the User and Fitter
1.5 Important Note
Keep these instructions in a safe place, pass on to the new owner in case of a change of ownership.
Make them available to the specialist in the case of repair work.
What to do when . . . ?
• the storage heater
does not get hot
• the storage heater
housing should get
extraordinarily
hot even in mild
weather
22
For the User
Check whether . . .
. . . the selector knob is set to
position 3.
. . . the corresponding fuses in
your fuse box are defective or
the FI switch has switched off.
Eliminate the cause!
If the following day the
storage heaters have still not
heated up, call a specialist.
Check whether . . .
. . . the fan can be switched on
with the room temperature
regulator.
If not, call a specialist.
. . . the fluff screen in the air inlet
grille is blocked.
Eliminate cause as described
in section 1.4.1!
For the specialist
Check whether . . .
. . . the control of the heating
element contactor is OK.
. . . there is a voltage at terminals
L1/L2/L3.
. . . whether the safety temperature
limiter (F1) has triggered.
"CLIC"
Check whether . . .
. . . the room temperature
regulator has switched on and
voltage is applied at terminal
LE.
. . . the fans are turning.
. . . the safety temperature
regulator "(N5, see page 3,
fig. 1) in the air outlet has
switched off.
. . . the control signal Z1 of the
charging control unit is applied
at terminal A1/Z1 in the
storage heater.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Wsp 3010Wsp 4010Wsp 5010Wsp 6010Wsp 7010

Table des Matières