2.

Control unit description

2.1.

Product features

ST 410/ST 411:
• 32 programs with up to 32 segments each
• 1 controlled heating/cooling ramp + soak per segment
• Soak times up to 99 hours 59 mins
• Ramp rates from 1 to 999°C/h or "FULL"
• Ideal for glass or ceramics use
• Programs can be altered while the kiln is in operation
• Program pause facility
• Program advance facility
• Keylock
• Program start delay facility – up to 99 hours 59 mins
• Continuation of kiln operation after a power failure
• Displays energy used
• Setpoint display
• Alarm buzzer
• Buzzer
• Temperature display either in °C or °F
• USB interface for data logging
ST 411 only:
• Integrated Wi-Fi module for connection to a wireless network
• Additional programmable switch output (e.g., automatic exhaust air flap)
2.2.

Technical information

Information
Protection class
Degree of pollution
IP rating
Supply
Fuse
Ambient temperature
Weight
Housing dimensions
Housing material
Bracket material
Connection cable
Description
2
2
IP51
100-240 V, AC, 50-60 Hz, 1.0 A
Micro-fuse, 3.15 A, 5 x 20 mm, slow-blow, ceramic, HRC
ROHDE item no.: 704851
-5°C to +30°C
0.5 kg
Width 80/68 mm x height 165 mm x depth 28 mm
Plastic, ABS, flame retardant, UL 94V-0
Plastic, ABS, flame retardant, UL 94V-0
Length 2 m, insulation PU, CPC 14 connector
45 / 280