Dometic FRIGO DC Notice D'utilisation page 18

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 46
All manuals and user guides at all-guides.com
Faults
9
Faults
9.1
Failure of the refrigeration system
In the event that the refrigeration system partially or completely fails without an
error message being shown on the display:
➤ First check the refrigeration system fuses.
A
NOTICE!
Broken fuses must be replaced by equivalent fuses. Fuses can be identified by
their shape, color and their fuse value. If a replaced fuse burns out again, con-
tact your service partner.
I
NOTE
If access to the fuses is restricted, contact your service partner.
The fuses for the compressor and the main power supply are located in the area
directly next to the vehicle battery. Further fuses are located in the interior on the
relay block on the rear wall.
Amper-
age
150 A
100 A
30 A
15 A
15 A
10 A
3 A
3 A
15 A
1 A
1 A
If the fault cannot be rectified, the refrigeration system may only be inspected
and repaired by an authorized Dometic service partner.
18
Identifica-
Consumer unit
tion color
Orange
Electrical compressor
Blue
Battery charger (only for
the supplementary
equipment "Stationary
Cooling")
Orange
Main supply
Blue
Evaporator fan 1
Blue
Evaporator fan 2
Red
Compressor, fan, sole-
noid valve
Violet
Control unit
Violet
Control unit
Blue
Earth
Black
Only for the supplemen-
tary equipment "Station-
ary Cooling"
Black
Only for the supplemen-
tary equipment "Station-
ary Cooling"
Frigo DC
Installation site
On the vehicle battery
On the vehicle battery
On the vehicle battery
In the interior on the rear wall
In the interior on the rear wall
In the interior on the rear wall
In the interior on the rear wall
In the interior on the rear wall
In the interior on the rear wall
In the interior on the rear wall
In the interior on the rear wall
EN