Total Reset
General reset operation erases memories, access code and will return all settings
to factory settings (see « SETTINGS PROGRAMMING » section pages 28-30).
1) Make sure the telephone is connected to a powered C.O. or PBX line.
2) Depress « RESET » key (On the small keypad located at the back of the unit).
3) While keeping « RESET » key depressed, pick-up the handset.
4) 2 sharp « beep » tones will be heard.
5) Release « RESET » key.
6) Enter general reset code on the keypad: « 1-5-9 ».
7) If the right code is entered, 2 sharp « beep » tones will be heard (Don't hang up
the handset).
8) Wait several seconds until 3 « beep » tones can be heard, confirming the
general reset operation.
9) Hang up the handset.
Securphone
NOTE:
in emergency mode if a "Total Reset" is done.
Setting access code:
Setting choice:
Partial reset
Partial reset operation will return almost all settings to factory settings, but the 4
digits programming access code as well as all numbers stored into memories will
be saved (see « LIST OF SETTINGS » section pages 29-30).
Heating resistor
Securphone
The
offers the possibility to use an internal heating resistor to avoid
moisture problems. This feature must be powered with the DC adaptor provided
in the pack. Connect the wires from DC adaptor as follows:
All manuals and user guides at all-guides.com
Urgence (Emergency) model needs to be re-programmed
04
Urgency: 1
Heating resistor power
24 Volts DC/AC 50Hz 35
mA