WARNING – BEST PRACTICES FOR OPTIMAL OPERATION 
Make  sure  that  the  air  filter  is  always  clean  and  in  good  working  condition  and  not  overly  obstructed.  An 
obstructed air filter will result in reduced air flow and higher outlet temperature. Continued operation WITH 
THE FILTER CLOGGED will drastically reduce the life of the heating elements. 
The unit must be inspected once a year by a qualified technician. 
Make sure that you have enough clearance in the front and the rear of the unit for service and maintenance. 
Although the unit is approved for zero clearance on these panels, it is definitely NOT a good practice to do it.  
 
3.0 Installation of the furnace 
The return air/ inlet connection is made on the rear of the unit and the supply plenum is connected in the front of the 
unit. The flanges supplied with the cabinet are 19" X 19" and can accommodate plenums of that size. The cabinet is also 
large enough so 20" X 20" supply plenums could be attached directly on the furnace. See Figure 1 for details. The unit is 
approved for installation with zero clearance on all parts of the cabinet including the floor (combustible floor) and also 
with zero clearance on the walls of the supply plenum. The unit can be installed directly on the floor, on the adjustable 
Return Air Plenum 
legs  (included)  or  suspended  to  the  ceiling  with  "plumber"  straps.  Please  see  figure  2A,  2B  and  2C  for  the  different 
installation configurations. Make sure to leave sufficient clearance in the front of the unit for the electrical connections 
and electrical service and in the rear of the unit for blower and motor maintenance and service. Please note that the air 
filter rack can be installed on the right or left side of the unit in addition to the rear (factory position). To change the 
filter rack position, refer to fig. 3. 
 
 
Supply Air Plenum 
Front of furnace 
Figure 1 
Figure 2B
Figure 2A
Floor (Combustible floor approved) 
 
 
 
 
 
 
 
 
 
 
 
 
 
Installed with the 
mounting legs supplied 
as standard equipment. 
See  the mounting 
procedure at the end of 
this manual
Figure 2C