Water Treatment; Plumbing Hook-Up; Site Requirements - Bunn Sure Immersion 220 Guide D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

• Unplug the machine or turn off the main switch before servicing the interior components of the machine.
• Never operate the machine without water.
• Never touch brew module, spouts, and hot water dispense pipes. They are HOT and could cause burns.
• The machine must be operated with clean water. Make sure to use water filters and/or softeners as needed.
Plumbing
1. These brewers must be connected to a cold water system with operating pressure between 20 and 90
psi (0.138 and 0.620 MPa) from a 1⁄4" or larger supply line. Install a regulator in the line when pressure
is greater than 90 psi (0.620 MPa) to reduce it to 50 psi (0.345 MPa).
2. Shut off valve should be present between water supply and machine.
3. Flush the water line and securely attach it to the inlet fitting at the rear of the brewer.
4. Turn on the water supply.
NOTE: Bunn-O-Matic recommends 1⁄4" copper tubing for installations of less than 25 feet and 3⁄8" for
more than 25 feet from the 1⁄2" water supply line. A tight coil of copper tubing in the water line will
facilitate moving the brewer to clean the counter top. Bunn-O-Matic does not recommend the use of a
saddle valve to install the brewer. The size and shape of the hole made in the supply line by this type of
device may restrict water flow.

Water Treatment

1. No Chlorine.
2. Water Hardness 6 to 10 grains or less total hardness
3. Water Filtration System

Plumbing Hook-Up

The plumbing connection is a 1/4"" male flare adapter located on the
lower rear of the machine as shown.
NOTE: Water pipe connections and fixtures directly connected to a
potable water supply shall be sized, installed, and maintained in
accordance with federal, state, and local codes.
As directed in the International Plumbing Code of the International Code Council and the Food Code Manual of
the Food and Drug Administration (FDA), this equipment must be installed with adequate backflow prevention to
comply with federal, state and local codes. For models installed outside the U.S.A., you must comply with the
applicable Plumbing /Sanitation Code for your area.

SITE REQUIREMENTS

WARNINGS